Model 8922 POTS Card Firmware Compatibility 
Notice

Document Number 8922-A2-ZK40-10

January 2006 

Do Not Install This Card Until You Have Checked 

Firmware 

Do not install this card into the Broadband Loop Carrier (BLC) until you have 
verified that you have the proper firmware in your SCP card. To determine the 
firmware level using the web interface, select 

System->Firmware

. Check the 

Running Firmware field.

The minimum revision of firmware required is:

z

03.03.00

 for SCP cards with ATM uplinks

z

04.01.00

 for SCP cards with IP uplinks

If your SCP card is at a firmware revision below the revision listed above, an 
upgrade is required before you can install the 8922 POTS card. Contact your 
technical support representative to obtain the latest SCP card firmware. 

After downloading and switching to a valid firmware release, immediately 
download at least the minimum firmware level into the alternate firmware 
bank to prevent an inadvertent switch to the wrong level. Then proceed with 
the installation of the line card.