88
Step 3: Select [MEM] mode;
Step 4: Press key [SYCLE START], run the program
6.3 Execution of Automatically Operation
1.
A one-block command is read from the specified program;
2.
The block command is decoded;
3.
The command execution is started;
4.
The command in the next block is read;
5.
Buffering is executed. That is the command is decoded to allow immediate execution;
CAUTION:
1.
Immediately after the preceding block is executed, execution of the next block can be started. This is
because buffering has been executed.
2.
Hereafter, memory operation can be executed by repeating the steps 4 to 6.
6.4 Stop Automatic Operation
There are two methods to stop the operation automatically. The first method is to input stop command at the
place where it is stop using program. The second method is that press hold button on the operation panel to make
it stop.
6.4.1 Program Stop M00
It will stop running as the M00 program is run, and just like single block, modal information will all be saved.
It will restart if you press cycle start button.
6.4.2 Program End M30
1.
Means main program end ;
2.
Stop automatic operation and in reset state;
3.
Return the starting point of the program.
6.4.3 Feed Hold
Press the [FEED HOLD] button can pause automatic operation. machine tool status is as follows after
pressing the feed hold button.
1.
Stop feed decelerate when machine is moving;
2.
Stop pause in the execution suspension;
3.
Stop after executing the motion of M, S, T.
Program will continue run after pressing the automatic cycle start button.
6.4.4 Reset
Pressing [RESET] button can take the automatic run over and machine is to reset state. If the reset button is
pressed when the machine is running, it will slow down and stop.
In addition, switching operation mode such as [MEM], [MDI], [DNC] can also stop machine (machine will
stop after finishing the current program).
6.5 Control of Cooling Fluid in the Automatic Operation
Function of [COOLANT] button on the operation panel is effective in automatic mode. The output status of
M08 will reverse as long as the cooling button is pressed.
6.6 Machine Tools, Auxiliary Function to Lock Operation
1.
If [MACH LOCK] button on operation panel is pressed in the operational mode of [MEM], [MDI] and
[DNC], machine will make [FEED SHAFT] lock and [AUXILIARY FUNCTION] lock switch between lock and
unlock. Default state is all unlock when machine is power on.