SET-UP PROCEDURES
Page 32
6.3 S
ET
-
UP
F
UNCTIONS
& V
ALUES
The following table lists the various Function Codes, the Functions Name,
Default Value and Range. Each Function will be explained in one of the fol-
lowing Sections.
Table 1: Functions List
Function
Code
Function Name
Default
Value
Value Range or Options
PROCESSOR FUNCTIONS
A0
Processor Identification
01
01 or 02 (Each Processor must have a unique ID number)
A1
Number of Engines
01
01 or 02
A2
One Lever Operation
00
00 - Disable; 01 - Enable
ENGINE FUNCTIONS *Throttle defaults are based on throttle profile selected.
E0
Select Engine Throttle Profile
06
01
Caterpillar (PWM) (8 to 92%)
02
Cummins Centry (Voltage) (0.9 to 4.5VDC)
03
Cummins Quantum (Voltage) (0.9 to 1.2- 4.0VDC)
04
Detroit Diesel (Voltage) (0.5 to 4.5VDC)
05
MTU or MAN (Current) (4.0 to 20mA)
06
Scania (Voltage) (0.4 to 3.0VDC)
07
Volvo (Voltage) (0.5 to 4.5VDC)
E1
Throttle in Neutral (Only available with Type
03 - Throttle Profile)
*
01.0 to 25.0%
E2
Throttle Minimum
*
01.0 to 97.0%. Will always be 3% below Maximum.
E3
Throttle Maximum
*
04.0 to 100.0%. Will always be 3% above Minimum.
E4
Throttle Maximum Astern
100.0
1.0 to 100.0%
E5
Throttle Pause Following Shift
00.5
00.0 to 05.0 Seconds.
E6
High Idle
00.0
00.0 to 20.0% of Throttle Maximum
E7
Active Synchronization
00
00 - Disabled; 01 - Enabled
CLUTCH FUNCTIONS
C0
Clutch Oil Interlock
00
00 - Not-Installed; 01 - Installed
C1
Clutch Oil Interlock Delay
05.0
00.5 to 10.0 Seconds.
C2
Reversal Pause
00
00 -In-Gear; 01 - Neutral
C3
Reversal Pause Time
03.0
00.0 to 16.0 Seconds.
C4
Reversal Pause Ratio
00
00 - 2:1 Ahd to Ast : Ast to Ahd
01 - 1:1 Ahd to Ast : Ast to Ahd
TROLL FUNCTIONS
L0
Troll Lever Range
00
00 - No Troll
01 - 20 Degrees - Type 1
02 - 35 Degrees - Type 2
03 - 45 Degrees - Type 3
L1
Troll Valve Function
00
00 - Normal, No Current when Off
01 - Inverse, No Current when Off
02 - Inverse, Maximum Current when Off
L2
Troll Minimum Pressure
14.0
01.0- 99.0%. Will always be less/more (normal/inverted) than Troll Maxi-
mum by at least 1%.
L3
Troll Maximum Pressure
27.0
02.0- 100.0%. Will always be more/less (inverted/normal) than Troll Min-
imum by at least 1%.
L4
Troll Throttle Limit
00
00 - 20% of Maximum Throttle
L5
Troll Pulse Duration
00.6
00.0- 09.9 Seconds. Time that the Troll will be commanded to Troll Pulse
Percentage every time Troll is engaged.
L6
Troll Pulse Percentage
27.0
00.0- 100.0%. Percentage of Troll command provided during Troll Pulse
Duration.
TROUBLESHOOTING FUNCTIONS
H0
Diagnostic
00
Input Voltage (+/- 0.5VDC)
Tachometer Sensor Frequency
Station 1 Lever A/D
Station 2 Lever A/D
Station 3 Lever A/D
Station 4 Lever A/D
Transfer Button, Stations 1, 2, 3 & 4
Software Revision Level
H1
Erase EPROM
00
Store to Erase (
For Authorized Personnel Only
)
H2
High Side Driver Fault Detection Enable
00 - 63
Error Status Enable
Содержание CruiseCommand 785CE
Страница 71: ...APPENDIX A 1...
Страница 72: ......
Страница 74: ...Appendix A 7 01 Page 2...
Страница 77: ...Page 5...
Страница 78: ...Page 6...
Страница 82: ...Page 10...
Страница 84: ...Page 12...
Страница 86: ...Page 14...
Страница 87: ...Page 15 Deutsch Connector Assembly...
Страница 88: ...Page 16...
Страница 89: ...Page 17...
Страница 90: ...Page 18...
Страница 94: ...Page 22...
Страница 97: ...APPENDIX B 1...
Страница 98: ......
Страница 150: ......
Страница 151: ...APPENDIX C 1...
Страница 152: ......
Страница 153: ...Page 3 Drawing 11748 Single Screw Two Stations...
Страница 154: ...Page 4...
Страница 155: ...Page 5 Drawing 11746 Single Screw Two Pluggable Stations...
Страница 156: ...Page 6...
Страница 157: ...Page 7 Drawing 11747 Twin Screw Two Stations...
Страница 158: ...Page 8...
Страница 159: ...Page 9 Drawing 11745 Twin Screw Two Pluggable Stations...
Страница 160: ...Page 10...