TROUBLESHOOTING
Page 5
B) If the voltage tested good, the circuit board needs repair or a
Circuit Board Kit needs to be installed.
1.7 SYMPTOM - T
HE
C
ONTROL
H
EAD
RED
INDICATOR
LIGHT
DOES
NOT
LIGHT
WHEN
IN
COMMAND
,
BUT
EVERYTHING
ELSE
WORKS
PERFECTLY
.
Cause
:
A)Incorrectly wired eight-conductor cable.
B) Defective red indicator light
Remedy
:
A)Verify brown wire connection to Terminal 2 of the Processor
and the Control Head.
B) Measure the DC voltage between Terminals 2 and 3 at the Con-
trol Head. The reading will be 1.00 to 2.00 volts in normal
operation. A measurement of 4.00 volts means the indicator
light is OPEN. Replace the Control Head or install a Control
Head Repair Kit.
1.8 SYMPTOM - N
O
TONES
OR
LIGHTED
INDICATOR
LIGHTS
AT
THE
C
ONTROL
H
EAD
,
AND
NO
LIGHTED
INDICATOR
LIGHTS
ON
THE
P
ROCESSOR
CIRCUIT
BOARD
.
Cause
:
A)No power to the Processor.
B) Polarity of the battery voltage reversed.
C) Fuse on the Processor circuit board blown.
Remedy
:
A)Verify the power source to the Processor.
B) Connect the red wire to the terminal labeled ‘+ ‘ and the black
wire to the terminal labeled ‘ - ‘.
C) Measure the battery voltage at the Processor. It is MANDA-
TORY to correct power source if voltage can exceed 40 volts
under any condition. Replace the fuse with the spare, which is
taped to the relay on the Processor circuit board. If the fuse
Содержание ClearCommand
Страница 56: ......
Страница 57: ...APPENDIX A 1 ...
Страница 58: ......
Страница 60: ...Appendix A 6 20 01 Page 2 ...
Страница 63: ...Page 5 ...
Страница 64: ...Page 6 ...
Страница 68: ...Page 10 ...
Страница 70: ...Page 12 ...
Страница 72: ...Page 14 ...
Страница 78: ...Page 20 ...
Страница 82: ...Page 24 ...
Страница 85: ...APPENDIX B 1 ...
Страница 86: ......
Страница 97: ...APPENDIX C 1 ...
Страница 98: ......
Страница 99: ...Drawing 11202F 1 ...
Страница 100: ... ...
Страница 101: ...Drawing 11202F 2 ...
Страница 102: ... ...
Страница 103: ...Drawing 11202F 3 Notes Page ...
Страница 104: ... ...