Installation and Operating Instructions V04 56
10.3 General data
●
—Standard
○
—Optional -—N/A
Type
Zeverlution
3680
Zeverlution
4000
Zeverlution
5000
communication:
RS485 / Ethernet / WiFi
●
/
○
/
○
Display
16 x 2 characters
Earth Fault Alarm
cloud based, audible and visible(AU)
Zero power output
Via connecting smart meter(AU)
Dimensions (W x H x D)
341 x395x172 mm
Weight
11kg
Cooling method
convection
Noise emission (typical)
<25 dB(A)@1m
Installation
indoor & outdoor
Mounting information
wall mounting bracket
DC connection
SUNCLIX
AC connection
screw terminalterminal
Operating temperature range
-25
℃
…+60
℃
Relative humidity
(non-condensing)
0% ... 100%
Max. operating altitude
4000m(>3000m derating)
Degree of protection (according
to IEC 60529)
IP65
Climatic category (according
to IEC 60721-3-4)
4K4H
Topology
H5
Self-consumption (night)
<1W
Radio technology
WLAN 802.11 b / g / n
Radio spectrum
2.4 GHz
Standby power
<8.5W