9.2 Display messages
Along with the various operating states, various messages may be shown on the
display, as follows.
State
Error
code
Description
Causes
Initializat-
ion
Waiting
Initial PV voltage is between minimum DC
input voltage and the start-up DC input
voltage of the inverter.
Checking
The inverter is checking the feed-in
conditions after the initial PV voltage
exceeds the start-up DC input voltage of
the inverter.
Reconnect
The inverter is checking feed-in
conditions after the occured fault has
been solved.
Normal
Normal
The inverter is feeding power into grid
normally.
Fault
1
SCI Fault
Communication between the master and
slave CPU has failed.
2
EEPROM R/W
Fault
Reading or writing of EEPROM has failed.
3
Rly-Check Fault Output relay has failed.
4
DC INJ. High
Output DC feed-in exceeds the permitted
upper limit.
6
High DC Bus
The voltage of DC bus exceeds the
permitted upper limit.
8
AC HCT Fault
Output current is abnormal
9
GFCI Fault
Groundfault detection circuit is abnormal
10
Device Fault
Unknown Error
33
Fac Fault
The grid frequency is outside the
permitted range.
34
Vac Fault
The grid voltage is outside the permitted
range.
Fault
35
No Utility Grid The utility cannot be detected, which may