Connection
~
11
~
5.
Connection
5.1
Preparation
Table 5-1: Cables and wiring
Type
Requirements
Maximum
length
Network
cable
1.
Comply with the standards for structured
cabling according to EIA/TIA-568.
2.
Shielded Ethernet cable (CAT-5E or higher).
3.
UV resistant if used outdoors.
100m
RS485
cable
1.
The same as network cable line
1000m
DRMs cable
(
DRED
)
1.
The same as network cable line
1000m
Remember to connect the Ethernet cable to the Ethernet port
(RJ45 LAN connectors) and not to the RS485 port.
5.2
Connection Area
The ZeverCom/ZeverCom WiFi collects inverter(s) data and events, and uploads
them to the ZeverCloud via the Internet. This section shows how to connect with
the inverter and ZeverCloud.
Fig. 5-1: Overview of the connection area
The description of the connection area is shown in the following Table 5-2.
Table 5-2: Function and Description of the connection area
Item
Function
Description
A
Power socket
Connect to power supply