67
Serial Port Programming
Wire Line
This mode is not supported in the Model 6203 for IP FSA systems.
VOX
This communications mode is designed for use with a conventional radio interface where
the Model 6203 uses its own internal circuitry to detect channel availability. If the Model
6203 detects noise above a threshold set by the VOX potentiometer, it thinks the channel
is busy and does not transmit. When this mode is selected the COR input is ignored by the
Model 6203. The Model 6203 attempts to transmit status changes as soon as they happen.
It does not need to receive a poll from the Model 26 in order to transmit (exception
reporting).
COR Communications Modes
There are two different COR (Carrier Operated Relay) communication modes:
TX on
COR High
and
TX on COR Low
. For the purposes of IP alerting, the
COR TX on COR
Low
mode is used and the COR input is always grounded.
Trunking Communications modes
This mode of operation is no longer supported in IP network-based systems.
“Alerts” Menu
This menu selection is accessed from the Main menu. It is used in the configuration of
alert commands and appears as shown in
when selected.
Figure 15: Serial Programming of Model 6203 - Alerts Menu
Содержание 025-9581M
Страница 1: ...Fire Station Alerting System Installation and Maintenance 025 9581M ...
Страница 6: ...6 025 9581M ...
Страница 40: ...Creating Console Positions 40 025 9581M ...
Страница 45: ...45 Installing the VoIP Gateway Server ...
Страница 78: ...Configuring Station Transponder Units 78 025 9581M ...
Страница 124: ...Installing the Station Transponder Units on Site 124 025 9581M ...
Страница 146: ...Using a Model 26 Fire Station Dispatcher for System Backup 146 025 9581M ...
Страница 188: ...Appendix C Using a Model 620x in a Model 26 based System 188 025 9581M ...
Страница 196: ...Fire Station Alerting System Installation and Maintenance 196 025 9581M ...