![ZETRON 025-9581M Скачать руководство пользователя страница 100](http://html.mh-extra.com/html/zetron/025-9581m/025-9581m_installation-and-maintenance-manual_932238100.webp)
Basic System Configuration on the Bench
100
Table 2: Pinout for Digital Input 1
Figure 36: Audio and Digital Input Interface Connections
Pin #
Signal Description
1
Audio , goes to channel card input (RX)
2
Digital Input, goes to channel card PTT Normally Open
3
Audio Input + , goes to channel card audio output (TX)
4
Audio Input - , goes to channel card audio output (TX)
5
Digital Input, from channel card PTT Common
6
Audio Output - , goes to channel card input (RX)
Note
The PTT signal input from the dispatch console channel card is
required for installations using radio to distribute PA audio to
stations or if customers wish to have PA Ready remain enabled
while the dispatch operator is speaking. The only alternative is
setting a fixed delay after key up, which gives the operator a pre-
set window within which to complete all announcements.
Audio and Digital Input Interface
950-0690
To network switch
Mic In / Pink
Line Out /
Speaker /
Green
Combined FSA Server and
VoIP Gateway Server
Keyb. Mouse
Network
Au
di
o I
n
A
udi
o O
ut
VGA
USB
Di
gi
ta
l O
ut
Left Audio
In & Out
Digital Input 1
To Dispatch Console
Channel Card
Audio and PTT
Not Used
USB to Serial
Adapter
Use the Zetron-
supplied sound card
709-7000
(Depending on the console
interface, you may have to rework
the other end of the cable.)
709-0001
802-0487
709-0055
Содержание 025-9581M
Страница 1: ...Fire Station Alerting System Installation and Maintenance 025 9581M ...
Страница 6: ...6 025 9581M ...
Страница 40: ...Creating Console Positions 40 025 9581M ...
Страница 45: ...45 Installing the VoIP Gateway Server ...
Страница 78: ...Configuring Station Transponder Units 78 025 9581M ...
Страница 124: ...Installing the Station Transponder Units on Site 124 025 9581M ...
Страница 146: ...Using a Model 26 Fire Station Dispatcher for System Backup 146 025 9581M ...
Страница 188: ...Appendix C Using a Model 620x in a Model 26 based System 188 025 9581M ...
Страница 196: ...Fire Station Alerting System Installation and Maintenance 196 025 9581M ...