ZeroKey ISAN10 Скачать руководство пользователя страница 1

 

 

 

2021-01-29 

ISAN10 & ISRL10 User Manual 

 

 

  

 
 
 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

  

 

 

 

 

 

 

 

 

 

 

 

 

ISAN10 & ISRL10 User Manual 

v1.1.0 

 

 

Содержание ISAN10

Страница 1: ...1 2021 01 29 ISAN10 ISRL10 User Manual ISAN10 ISRL10 User Manual v1 1 0 ...

Страница 2: ... EVENT SHALL ZEROKEY ITS DIRECTORS OFFICERS EMPLOYEES OR AGENTS BE LIABLE FOR ANY INDIRECT SPECIAL INCIDENTAL OR CONSEQUENTIAL DAMAGES INCLUDING DAMAGES FOR LOSS OF PROFITS LOSS OF BUSINESS LOSS OF USE OR DATA INTERRUPTION OF BUSINESS AND THE LIKE EVEN IF ZEROKEY HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES ARISING FROM ANY DEFECT OR ERROR IN THIS MANUAL OR PRODUCT SPECIFICATIONS AND INFORM...

Страница 3: ...rcumstances Do NOT immerse in liquid s No serviceable parts inside Clean only with a damp cloth to prevent static build up Certification and Compliance The ISAN10 and ISRL10 are certified through SGS Group for use in hazardous locations Rated as Class 1 Division 1 IP65 The radio used in this device has been certified for use according to Federal Communications Commission FCC Industry Canada IC and...

Страница 4: ...g two conditions 1 This device may not cause interference 2 This device must accept any interference including interference that may cause undesired operation of the device L émetteur récepteur exempt de licence contenu dans le présent appareil est conforme aux CNR d Innovation Sciences et Développement économique Canada applicables aux appareils radio exempts de licence L exploitation est autoris...

Страница 5: ... 3 3 1 STATUS LED 8 COLOUR PATTERN 8 MEANING 8 3 4 INSTALLATION 9 3 4 1 CHOOSING THE LOCATION Error Bookmark not defined 3 4 2 INSTALLING THE MOUNT 9 3 4 3 INSTALLING THE DEVICE 9 4 OPERATION 10 4 1 SMART SPACE CONFIGURATION 10 5 MAINTENANCE AND PRODUCT CARE 11 5 1 MAINTENANCE 11 5 2 GENERAL CARE 11 5 3 CLEANING 11 5 4 OPERATING TEMPERATURE 11 6 REPAIRS AND DISPOSAL 12 6 1 FIRMWARE UPDATES 12 6 2 ...

Страница 6: ...wing sources for additional information and for product and software updates ISAN10 ISRL10 Resources For more information and the most up to date user manual please visit our website https zerokey com which contains additional product specifications user documentation and notices Included product documentation Your product package includes documentation detailing the setup and operation of the ISA...

Страница 7: ...its are the listening nodes that monitor transmissions from the mobile units in the area and send the information back to the gateway units so the server can determine distance and position The Anchor units listen for mobile units while Relay units which have two separate radios can also retransmit data from distant nodes to the gateway Should the Anchor be too far from the gateway it can send its...

Страница 8: ...r ceiling 3 3 INDICATORS 3 3 1 STATUS LED A multicolored LED is used to signal the current status of the Anchor or Relay unit The Status LED will blink its status every 2 to 5 seconds in order to conserve power COLOUR PATTERN MEANING Blinking blue DFU mode receiving firmware update Blinking green On normal operation Blinking red On with low battery level Solid white Pairing unit is waiting for a f...

Страница 9: ...nchor and Relay node chosen See Safe Space Site Design Considerations the mount can be installed to almost any wall or ceiling surface either using two self tapping screws or by welding the mount in place 4 2 INSTALLING THE DEVICE The Anchor or Relay unit can be clipped into the mount by inserting one tab in the lower mounting arm and then pushing the unit into the upper mounting arm There are thr...

Страница 10: ...code 5 OPERATION 5 1 SMART SPACE CONFIGURATION Once the unit is operating it will continue to operate until it has exhausted its batteries The unit should be checked weekly to make sure that the device is still operating normally and the batteries are not running critically low 5 2 BATTERY SERVICING Both Anchor and Relay units use long lasting lithium thionyl chloride primary batteries which CANNO...

Страница 11: ... to be handled in a reasonable manner to ensure reliable and continued use 6 3 CLEANING The device can be cleaned using a moistened soft cloth and nonabrasive hand dish soap Wipe dry to prevent any moisture build up WARNING DO NOT IMMERSE 6 4 OPERATING TEMPERATURE This device is designed to operate from 40 C to 60 C ambient Do not place unit in direct sun for extended periods without proper ventil...

Страница 12: ...E Units that have been damaged or have failed to operate in the field must be returned for repair or replacement with a few exceptions If the battery has been physically compromised or has been found to be defective the unit can NOT be legally shipped by any carrier If the unit is intact but has ceased to operate it can be returned via an RMA request to our repair center Please contact your plan a...

Отзывы: