44 • Illustrations - Master/Satellite Wiring
ILLUSTRATIONS
Master/Satellite Wiring
GRD
ON
GREEN
WHITE
BLACK
RED
OFF
GRN
12 GA
WHT
12 GA
BLK
12 GA
RED
12 GA
4X4 ELEC BOX
CUSTOMER
CONNECTIONS
115-208/230V-1-60
PAR
AG
O
N
DE
FR
OS
T
TI
M
ECL
O
CK
T
1
N
2
3
4
X
OR
G
18
G
A
ORG 18 GA
LIGHTS
(SEE AUX
DIAGRAM
ORG OR
BLK
WHT
KL
IX
ON
(F
AN
S)
BLU
BL
U
A B C D E F G H 1 2 3 4 5
SAFETY CUT OUT
THERMOSTAT
W/ BROWN LEADS
SET TO 85°F
OPEN ON RISE
BRN
BRN
DEFROST
BLK
BLK
BLK W/GRY 12 GA
FIELD INSTALLED
SOLENOID VALVE
SHIPPED LOOSE
120VAC
WHT/BLU 18 GA
BLU 18 GA
TEMPERATURE
CONTROL
RED/YELLOW
CLOSE ON RISE
OPEN ON DROP
BLU 18 GA
REPRESENTS EGRESS
THROUGH CASE
RE
D 1
8 G
A
BL
K
RED
W
HT
/R
ED
BLK
W
HT
18
GA
DOOR
SILL
MULLION
LI
GH
T S
W
IT
CH
REPRESENTS
EGRESS
THROUGH CASE
FANS
M
M
BLU (RIBBED)
BLU (SMOOTH)
CB
ORG
18 GA
ON 4 & 5
DOOR
ONLY
20 AMPS
YEL
14 GA
FAN TEST WIRE
ADJUSTABLE DEFROST
TERMINATION SET @ 50°F
OPEN ON RISE CLOSE ON DROP
USE RED AND BLUE DOT
R
B
Y
CONDUIT
OPTIONAL 4X4
ELEC BOX ON
TOP OF CASE
4
6
0
1
RE
LA
Y
SPD
T
30A
,
120V
AC
GRY 14 GA
GRY
14 GA
REPRESENTS EGRESS
THROUGH CASE
BLK 12 GA
RED 12 GA
YEL 14 GA
WHT W/YEL 14 GA
BRN 14 GA
WHT W/BRN 14 GA
REPRESENTS EGRESS
THROUGH CASE
CONDUIT FROM
SATELLITE CASE
BLU 14 GA
P
OPTIONAL
CONDENSATE
PUMP
115V-1-60
WHT
BLK
OPTIONAL
TO TB 4
TO TB G
OPTIONAL
CONDENSATE EVAPORATOR 115V-1-60
MOUNTED ON TOP OF CASE
PLUGGED INTO CONDENSING UNIT
OR POWERED BY CUSTOMER
CB
BRN
14 GA
OPTIONAL
FIGURE 30: LOW TEMP
GRD
ON
GREEN
WHITE
BLACK
RED
OFF
GRN
12 GA
WHT
12 GA
BLK
12 GA
RED
12 GA
4X4 ELEC BOX
CUSTOMER
CONNECTIONS
115-208/230V-1-60
O
RG
1
8
GA
ORG 18 GA
LIGHTS
(SEE AUX
DIAGRAM
ORG OR
BLK
WHT
KL
IXO
N
(F
AN
S)
BLU
BL
U
A B C D E F G H 1 2 3 4 5
SAFETY CUT OUT
THERMOSTAT
W/ BROWN LEADS
SET TO 85°F
OPEN ON RISE
BRN
BRN
DEFROST
BLK
BLK
BLK W/GRY 12 GA
RE
D
18
GA
BL
K
RED
W
HT
/RE
D
BLK
W
HT
18
GA
DOOR
SILL
MULLION
LIGH
T S
W
IT
CH
REPRESENTS
EGRESS
THROUGH CASE
FANS
M
M
BLU (RIBBED)
BLU (SMOOTH)
CB
ORG
18 GA
ON 4 & 5
DOOR
ONLY
20 AMPS
YEL
14 GA
FAN TEST WIRE
ADJUSTABLE DEFROST
TERMINATION SET @ 50°F
OPEN ON RISE CLOSE ON DROP
USE RED AND BLUE DOT
R
B
Y
REPRESENTS EGRESS
THROUGH CASE
BLU 14 GA
YEL 14 GA
WHT W/YEL 14 GA
BRN 14 GA
WHT W/BRN 14 GA
REPRESENTS EGRESS
THROUGH CASE
CONDUIT FROM
SATELLITE CASE
4
5
1
2
6
3
7
8
9
A
B
RE
LA
Y
3P
DT
120V
A
C
BLK 12 GA
P
OPTIONAL
CONDENSATE
PUMP
115V-1-60
WHT
BLK
OPTIONAL
TO TB 4
TO TB G
OPTIONAL
CONDENSATE EVAPORATOR 115V-1-60
MOUNTED ON TOP OF CASE
PLUGGED INTO CONDENSING UNIT
OR POWERED BY CUSTOMER
CB
BRN
14 GA
OPTIONAL
Содержание Highlight MERCHANDISER RHZC30
Страница 2: ......
Страница 4: ......
Страница 25: ...Illustrations Leveling 21 Illustrations Leveling Figure 3 Positioning Hat Channel Rails Refer back to page 5...
Страница 38: ...34 Illustrations Under Case Return Air Flow Illustrations Under Case Return Air Flow Figure 19...
Страница 39: ...Illustrations Penetration Sealing 35 Illustrations Penetration Sealing Figure 20...
Страница 40: ...36 Illustrations P trap Installation Illustrations Figure 21 45 ELBOW SUCTION LINE P trap Installation...