background image

Installation, Service and User

 

 

INSTRUCTIONS 

FOR THE

 

ZERO DOMESTIC

 

MODELS:

 

GF180IP, GF215, 

& GF200

 

SINGLE LID CHEST FREEZER

 

 

 

2-WAY:  L.P. Gas & 230V Electric

 

ZERO APPLIANCES (PTY) LTD 

Cat. I

3+ (28–30/37) 

& I

3B/P (30)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WARNING: THIS APPLIANCE MUST BE 

EARTHED

 

ENSURE THAT THE GAS SUPPLY HOSE IS NOT IN 

CONTACT WITH OR NEAR THE BURNER BOX

Содержание GF180IP

Страница 1: ...DOMESTIC MODELS GF180IP GF215 GF200 SINGLE LID CHEST FREEZER 2 WAY L P Gas 230V Electric ZERO APPLIANCES PTY LTD Cat I3 28 30 37 I3B P 30 WARNING THIS APPLIANCE MUST BE EARTHED ENSURE THAT THE GAS SU...

Страница 2: ...s LPG at 3 0 kPa Declared rate Injector size 0 42mm diameter marked 13 Gas consumption 34 2 g h Electrical Supply 230V Mains Electricity 0 320kW This appliance is a single lid single bin chest type fr...

Страница 3: ...ANT INFORMATION FOR THE INSTALLER Only an LP gas installer registered with the Liquefied Petroleum Gas Association of South Africa may install a gas installation The installation must be installed in...

Страница 4: ...before beginning to use this appliance Retain these instructions for future reference LP GAS OPERATION After initial installation after changing gas cylinder after servicing etc the gas pipes may cont...

Страница 5: ...ely Do not store or use gasoline or other flammable vapour and liquid in the vicinity of this or any other appliance USER OPERATING INSTRUCTIONS TO START ELECTRIC OPERATION 1 Make sure that the gas su...

Страница 6: ...any unburnt gas to disperse and then repeat the ignition steps TROUBLESHOOTING IF THE APPLIANCE FAILS TO WORK Check the following points before calling for service 1 That the instructions for starting...

Страница 7: ...tances should you try to repair it as the unit is pressurized with hydrogen and may explode if welding is attempted on the unit Call a qualified service technician Turn off the gas or electric supply...

Страница 8: ...y according to the ambient temperature the location of the freezer the frequency with which the lid is opened and the volume and concentration of products stored in it 11 You avoid packing products in...

Страница 9: ...ner dust insect nests waste paper etc WARNING The needle valve screw used for admitting the ammonia hydrogen filling charge to an absorption unit is fitted to the unit s reservoir It is a strictly app...

Страница 10: ...IED TECHNICIAN Check jet is clean if not clean with solvent and blow dry Do not try to clean with pin or similar If the burner will not stay alight check position of the thermocouple head and the func...

Страница 11: ...ve the appliance from dwelling areas GAS BURNER PARTS LIST 1 SANS BRASS HOSE TAIL 2 FLAME FAILURE DEVICE 3 M10 NUTS 4 M10 x 3 8 UNF JET HOLDER 5 M10 x 1 JET NUT 6 JET MARKED 13 7 MIXING TUBE 8 BURNER...

Страница 12: ...ppliances co za guarantee form Complete the online form and click submit Or scan the above QR code with your smart device which will take you to the form Complete the online form and click submit WARN...

Отзывы: