22
Usage log information
The following information is displayed on the left side of the Technical tab:
Service Remaining days
Calculated based on dates. Warning when remaining 10% is reached
Last Data Sync
Date and time of the last data exchange via the internet
Last Restart
Date and time of the last restart o the app
Software Version
Installed software version number
Cup Size
Current setting for cold drink’s cup
Jug Size
Current setting for cold drink’s jug
CO
2
level
Not currently used
Enable still
Enable/disable dispensing of still water
Enable sparkling
Enable/disable dispensing of sparkling water
Enable Manual
Enable/disable manual dispensing (the ‘hand’ control for the end user)
Enable Cup / Jug
Enable/disable portion control for cold drinks for the two drink sizes
Water Temp Cold
Current dispensing temperature for cold drinks. Please note, the machine will
work to achieve the temperature indicated under the Cold Drinks settings
Total Chilled
Total chilled still water dispensed by the machine since start of operations
Total Ambient
Total ambient temperature water dispensed by the machine since start of operations
Running Total Water
Running total of dispensed amount since last filter change
Filter Change Date
Date of the last Filter replacement. Reset using the ‘Replace Filter’ button
Filter Life Days
Preset life span of the filter in days (default = 180 days)
Filter Life Litres
Preset life span of the filter in litres (default = 4000 litres)
Filter Life Remaining Days
Calculated based on dates. Warning when remaining 10% is reached
Filter Life Remaining Litres
Calculated based on usage. Warning when remaining 10% is reached
CO
2
Running Total
Total sparkling water dispensed in litres since the last CO2 canister replacement.
Reset using the ‘Replace CO
2
’ button
CO
2
Capacity Litres
Preset number of litres of sparkling water achievable at average setting based on
the standard canister size (600 g of CO
2
producing 75 litres of sparkling water)
CO
2
Remaining Litres
Calculated based on usage. Warning when remaining 10% is reached
Machine ID
Machine ID set-up at the factory and used to identify the machine on the web porta
Machine Num
Last part of the Machine ID
Installation date
Date of first launch of the tablet app
Last Service Date
Date of last major service. Reset using the ‘Reset Service Date’ button
Service Interval Days
Preset at 180 days
Variable
Description