Z 2500-130/150
76
Specifications
www.zepro.com
18.2
Maximum power consumption - Minimum recommended conductor cross sectional area
Hydraulic unit 7100
24 volt
Pump - Motor unit
200 A
Magnet (hydraulic unit)
2.10 A
Magnet (electric safety valve)
0.75 A
Solenoid
0.85 A
Minimum recommended conductor cross sectional area
(copper cables, plus and minus cables)
Control cable
1.5 mm
2
Supply cable, L < 8 m
35 mm
2
Supply cable, L = 8 - 15 m
35 mm
2
Supply cable, L > 15 m
50 mm
2
Battery
Min. capacity, I
min
(available for lift)
170 Ah
Min. voltage during operation, U
min
(at lift)
18 Volt
Z 2500 ( 200 bar)
Image 91. Maximum power consumption - Minimum recom-
mended conductor cross sectional area
-
+
-
+
L
L
U
min
I
min
I
min
U
min
18.3
Battery maintenance
When storing for longer than 1 week, you are recommended to disconnect the lift from the battery via the main
switch or by releasing the lift’s main fuse, in order to reduce the risk of the battery discharging. The length of
time the vehicle can be stored without the battery’s charge level becoming too low depends on the condition
of the battery, the charge level before storage and how much power the vehicle’s other components take from
the battery. After a period of storage, the battery must always be charged fully before operating the lift.
When installing the lift and when carrying out service and repair work, when the lift is operated repeatedly
without the vehicle being started and used, the battery charger must be used between operations to maintain
the battery’s charge level.
The battery charger must not be connected when operating the lift. Risk of damage.
NOTE.
Ensure that the lift has
access to the minimum
recommended power
capacity (I
min
)
.
Some ve-
hicles have restrictions
regarding the amount of
power the lift can access
from the existing battery.
NOTE.