14
has “+” signs where the positive (longer) lead goes. The negative side of the caps have white
stripes pointing to the negative lead.
d. Install all of the smaller electrolytic caps (C2 ,C5 ,C8 ,C12). Solder and clip the leads.
16
e. Now install the three big electrolytic caps (C9 ,C10 ,C11).
17
Solder and clip the leads
18
, but
put one of these clipped leads aside for use in the next step.
WARNING:
The big electrolytic caps (C9 ,C10 ,C11) are likely to explode if they are installed
backwards, which could result in personal injury. Install in STRICT CONFORMANCE with
these instructions!
f. Before moving on, double check the orientation of each of the electrolytic caps. Make sure the
stripe on each electrolytic cap is in the same direction as each cap in the picture.
19
14
15
16
17
18
19