background image

WWW.ZEPHYRONLINE.COM

JAN21.0101

Typhoon

AK2100CS, B, W 
AK2136CS, B, W 
AK2142CS 
AK2148CS 

EN   Use, Care, and Installation Guide 

FR   Guide d’utilisation, d’entretien et d’installation

Hurricane

AK2500CS, B, W 
AK2536CS, B, W

Cyclone

AK6500CS, B, BS, W 
AK6536CS, B, BS, W 
AK6542CS

Airflow  Control  Technology

TM

C  

C  

Airflow  Control  Technology

TM

C  

C  

Содержание Cyclone AK6500BS

Страница 1: ...B W AK2142CS AK2148CS EN Use Care and Installation Guide FR Guide d utilisation d entretien et d installation Hurricane AK2500CS B W AK2536CS B W Cyclone AK6500CS B BS W AK6536CS B BS W AK6542CS Air...

Страница 2: ...2 Typhoon Hurricane Cyclone Use Care and Installation Guide T YPHOON HURRICANE CYCLONE UNDER CABINET CORE...

Страница 3: ...2 AK25 Hood Speci cations 13 AK65 Hood Speci cations 14 Electrical Supply 15 Cable Lock 15 Rectangular Vertical Ducting Preparation 16 Rectangular Horizontal Ducting Preparation 17 18 Mounting the Hoo...

Страница 4: ...ecting means cannot be locked securely fasten a prominent warning device such as a tag to the service panel General Safety WARNING Warning means that failure to heed this safety statement may result i...

Страница 5: ...es within walls ceilings attics crawl spaces or garages WARNING WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING a Installation work and electrical wiring m...

Страница 6: ...conformance with National Electrical Code ANSI NFPA 70 latest edition or CSA standards C22 1 94 Canadian Electrical Code Part 1 and C22 2 No 0 M91 latest edition and all local codes and ordinances If...

Страница 7: ...tion adapter AK21 AK25 6 Round transition adapter AK65 pre installed on top of hood 3 1 4 x10 rectangular cover plate pre installed on back of hood 3 1 4 x10 rectangular vertical transition adapter 3...

Страница 8: ...h damper 30 Ft x Ft Ft Ft Ft 6 7 8 10 Round roof cap 30 Ft x Ft Subtotal column2 Subtotal column1 Total ductwork Maximum Duct Length For satisfactory air movement the totalductlengthshould not exceed...

Страница 9: ...9 Typhoon Hurricane Cyclone Use Care and Installation Guide ZEPHYRONLINE COM Installation Instructions Mounting Height Clearance Ducting 36 24 min 32 max...

Страница 10: ...een the two transitions as possible Minimum mount height between range top to hood bottom should be no less than 24 Maximum mount height should be no higher than 32 It is important to install the hood...

Страница 11: ...joints w certi ed Silver Tape or Duct Tape Fire Hazard NEVER exhaust air or terminate ductwork into spaces between walls crawl spaces ceilings attics or garages All exhaust must be ducted to the outsi...

Страница 12: ...1 7 16 9 15 16 30 28 1 16 36 34 42 39 3 4 48 45 3 4 5 1 16 2 3 4 8 5 8 30 11 5 16 36 12 1 2 42 12 1 2 48 12 1 2 1 15 16 elec k o 30 29 3 4 36 35 3 4 42 41 3 4 48 47 11 16 30 14 36 17 42 19 7 8 48 22 7...

Страница 13: ...nd Installation Guide ZEPHYRONLINE COM Installation Instructions 30 29 3 4 36 35 3 4 14 5 8 7 1 8 1 7 8 11 1 4 3 3 4 11 7 8 C L 3 3 4 6 7 8 elec k o TOP SIDE FRONT BACK 8 5 8 1 1 8 6 7 8 30 27 7 8 36...

Страница 14: ...UNDER CABINET CORE Installation Instructions 3 1 16 1 7 16 9 15 16 30 27 7 8 36 33 7 8 42 39 7 8 4 1 2 1 3 16 8 5 8 11 7 8 2 elec k o 30 29 3 4 36 35 3 4 42 41 3 4 30 14 36 17 42 20 C L 15 3 8 22 1 4...

Страница 15: ...extension cord or adapter plug with this appliance Follow national electrical codes or prevailing local codes and ordinances This appliance requires a 120V 60Hz electrical supply and connected to an...

Страница 16: ...he Cyclone is pre con gured for 6 round vertical ducting 1 Using a Philips head screwdriver remove the screws and round vertical transition adapter from top of hood body 2 Replace round vertical trans...

Страница 17: ...clone is pre con gured for 6 round vertical ducting 1 Using a Philips head screwdriver remove the screws and round vertical transition adapter from the top of the hood 3 Typhoon ONLY Remove the two pl...

Страница 18: ...ransition adapter Do not secure to hood body yet 6 Place 3 1 4 x10 rectangular collar on back of hood and secure using the screws that previously secured the rectangular cover plate 5 Place 3 1 4 x10...

Страница 19: ...nd Installation Guide ZEPHYRONLINE COM Installation Instructions Mounting the Hood bottom panel lighting harness wood blocking installation screws and key holes duct work residue cups safety grilles e...

Страница 20: ...emoving bottom panel Take care not to scratch side panels during removal 5 Install 4 wood screws to cabinet bottom by following the installation screw hole dimensions on Page 12 14 These screws will b...

Страница 21: ...21 Typhoon Hurricane Cyclone Use Care and Installation Guide ZEPHYRONLINE COM Features Controls Q 2 3 1 4 1 4 4 5 6 AK21 Capacitive Touch...

Страница 22: ...22 Typhoon Hurricane Cyclone Use Care and Installation Guide T YPHOON HURRICANE CYCLONE UNDER CABINET CORE Features Controls 1 1 2 3 1 AK25 Electronic Touch...

Страница 23: ...ower On Off Speed Selection 1 Lights Off Dim Bright 2 BLOWER ON OFF SPEED SELECTION 0 is off 1 is low speed 2 is medium speed and 3 is high speed LIGHTS OFF DIM BRIGHT 0 is off 1 is dim and 2 is brigh...

Страница 24: ...al housing All hoods are equipped with dishwasher safe residue cups to collect cooking residue during the self cleaning function Cooking residues are often automatically lique ed and can accumulate in...

Страница 25: ...ing Instructions 1 Power on blowers at Speed 1 2 With nozzle on spray squirt grease cutting detergent onto blower wheel blades 30 35 times Repeat for each blower Leave blower on for 10 minutes Deterge...

Страница 26: ...icro ber cloth Always rub in the direction of the stainless steel grain To remove heavier grease build up use a liquid degreaser detergent After cleaning use a non abrasive stainless steel polish clea...

Страница 27: ...p fails please contact Zephyr to order replacement parts See the list of parts and accessories page for part numbers and contact information LED Removal FIG C 1 Remove the screws from the bottom panel...

Страница 28: ...ts ACT enables the installer to easily set the maximum blower speed to one of two most commonly speci ed CFM levels 390 or 290 CFM The usage of ACT may not be necessary for your installation Please ch...

Страница 29: ...d Q 2 3 level indicators illuminate 390 max CFM if speed Q 2 level indicators illuminate 290 max CFM Model Hurricane AK25 With hood off hold down the power button for 5 seconds If all speed level indi...

Страница 30: ...3 screws securing PC board plate to access PC board FIG D2 Model Hurricane AK25 2 Remove PC board plate by 2 screws FIG D4 3 Remove 2 screws securing PC board assembly to access PC board FIG D5 1 Rem...

Страница 31: ...NG DIAGRAM WHITE GREY BROWN BLUE WHITE GREY BROWN BLUE MOTOR MOTOR RED RED YELLOW YELLOW WHITE GREY BROWN BLUE AC 120V BODY GREEN WHITE BLACK LED LED AK65C WIRING DIAGRAM B W B W B W GREY BLACK BLACK...

Страница 32: ...The hood is not secured in place Check the installation of the hood The blower is working but the lights are not The LED light connector is disconnected Connect the LED light connector Defective LED l...

Страница 33: ...3 Residue Cup AK25 AK65 56160007 Safety Grille Stainless AK21 50220024 Safety Grille Black AK21 50220025 Safety Grille White AK21 50220026 Safety Grille Stainless AK25 AK65 50220022 Safety Grille Blac...

Страница 34: ...34 Typhoon Hurricane Cyclone Use Care and Installation Guide T YPHOON HURRICANE CYCLONE UNDER CABINET CORE Notes...

Страница 35: ...technician come to your home to repair remove or reinstall the Products After the first year from the date of your original purchase you are also responsible for all labor costs associated with this w...

Страница 36: ...product Please take a moment to register your new Zephyr product at www zephyronline com registration Zephyr Ventilation 2277 Harbor Bay Pkwy Alameda CA 94502 1 888 880 8368 Prompt registration helps...

Отзывы: