background image

JAN06.0101

Содержание Bogart EBO-E36ASX

Страница 1: ...JAN06 0101...

Страница 2: ...eave these Instructions with this unit for the owner OWNER Please retain these instructions for future reference Safety Warning Turn off power circuit at service panel and lock out panel before wiring...

Страница 3: ...d 6 Parts not supplied 6 Dimensions and clearances 7 Installation Instructions 8 Venting methods 8 Preparation 8 Installation Ductwork Calculation Sheet 9 Installation 10 Electrical connection 12 Desc...

Страница 4: ...his Hood With Any External Solid State Speed Control Device WARNING TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE a Never leave surface units unattended at high settings Boilovers cause smoking and gr...

Страница 5: ...local codes and ordinances A U L or C S A listed conduit connector must be provided at each end of the power supply conduit at the range hood and at the junction box Copies of the standards listed may...

Страница 6: ...unit PARTS NOT SUPPLIED Duct conduit and all tools required for installation Ductless Recirculating Kit to be used only in the Ductless recirculating version includes charcoal filter charcoal filter s...

Страница 7: ...ths 24 to 32 bottom of canopy to cooking surface ceiling CenterLine 14 6 8 26 12 12 Ducting and conduit area passage Duct bends are not considered 22 1 4 42 36 15 3 4 8 13 5 3 8 min 35 13 16 max 49 7...

Страница 8: ...Pipe PREPARATION Do not cut a joist or stud unless absolutely necessary If a joist or stud must be cut then a supporting frame must be constructed Fittings material is provided to secure the hood to m...

Страница 9: ...wall cap with damper 6 Round roof cap 6 Round to 3 1 4 x 10 rect transition 6 Round to 3 1 4 x 10 rect transition 90 elbow 7 8 round 90 elbow 7 8 round 45 elbow 7 8 Round wall cap with damper 7 8 Rou...

Страница 10: ...s will anchor to added studs Replace drywall and refinish 9 Determine and make all necessary cuts in the wall for the vent system Install the vent system before the canopy hood See Venting methods and...

Страница 11: ...cessive Weight Hazard Use two or more people to move and install range hood Failure to do so can result in back or other injury 17 Level the appliance using a carpenters level across bottom of hood wi...

Страница 12: ...AND IT MUST UNDER NO CIRCUMSTANCES BE CUT OR REMOVED Failure to do so can result in death or electrical shock Facing the front of the range hood remove the left knockout and the Junction box cover an...

Страница 13: ...upport bracket Duct cover support bracket Upper duct cover TOP VIEW 25 Check all light bulbs to make sure they are secure in their sockets Turn power on in service panel Check lights and blower operat...

Страница 14: ...n of the hood 1 Control panel 2 Grease filter 3 Grease filter release handle 4 Halogen lamp position and nr of lamps may vary 5 Hood canopy 6 Duct cover 7 Air outlet used for Ductless version only 1 6...

Страница 15: ...ttention The control ball flashes orange to indicate the saturation of the charcoal filter even if the hood is used in the extraction mode and no charcoal filter is fitted In this case perform the sig...

Страница 16: ...oker hood s Control Ball flashes green orange red in sequence then replace the battery Remote Control Maintenance Clean the remote control using non abrasive detergents Follow the instructions below i...

Страница 17: ...ing non aggressive detergents either by hand or in the dish washer which must be set to a low temperature and a short cycle When washed in a dish washer the grease filter may discolour slightly but th...

Страница 18: ...g area are affecting the ventilation of the hood 3 Blocking in the duct opening or ductwork 4 The direction of duct opening is against the wind 5 Using the wrong size of ducting 1 Metal filter is loos...

Страница 19: ...nce misuse abuse accident Improper installation and failure to follow installation instructions When product is used commercially or other than its intended purpose Damaged because of improper connect...

Страница 20: ...rcoal replacement filter duct cover extension kit internal blower 600 cfm in line blower 1100 cfm EBI 600A EBN 1100A Z1C 00BO Z0F C060 ZRC 00BO Part Description Part halogen bulb 12V 20 W metal filter...

Страница 21: ...21 www zephyronline com...

Страница 22: ...22...

Отзывы: