Installation –
Mounting Height & Clearance
6
www.zephyronline.com
DUCTING
A minimum of 6” round duct must be used to
maintain maximum air fl ow effi ciency .
Always use rigid type metal ducts only. Flexible
ducts could restrict air fl ow by up to 50%.
Also use calculation (on page 5) to compute total
available duct run when using elbows, transitions
and caps.
ALWAYS, when possible, reduce the number or
transitions and turns. If long duct run is required,
increase duct size.
If turns or transitions are required; install as far
away from insert duct output and as far apart,
between the two as possible.
Minimum mount height between range top to
cabinet bottom should be no less than 26”.
Maximum mount height should be no higher than
36”.
It is important to install the liner at the proper
mounting height. Liners mounted too low could
result in heat damage and fi re hazard; while liners
mounted too high will be hard to reach and will
lose its performance and effi ciency.
If available, also refer range manufacturer’s height
clearance requirements and recommended liner
mounting height above range.
Vertical Ducting:
6” round minimum
Horizontal Ducting:
N/A
DAMAGE-SHIPMENT / INSTALLATION:
• Please fully inspect unit for damage before
installation.
• If the unit is damaged in shipment, return the
unit to the store in which it was bought for
repair or replacement.
• If the unit is damaged by the customer, repair
or replacement is the responsibility of the
customer.
• If the unit is damaged by the installer (if other
than the customer), repair of replacement must
be made by arrangement between customer
and installer.
26” min.
36” max.
36”