Installation –
Mounting Height & Clearance
6
www.zephyronline.com
DUCTING
A minimum of 6” round duct must be used to
PDLQWDLQPD[LPXPDLUÀRZHI¿FLHQF\
Always use rigid type metal ducts only. Flexible
GXFWVFRXOGUHVWULFWDLUÀRZE\XSWR
Use calculation worksheet to compute total duct
ZRUN3DJH
ALWAYS, when possible, reduce the number of
transitions and turns. If a long duct run is required,
increase duct size from 6” to 7” or 8”.
If turns or transitions are required: Install as far
away from duct opening and as far apart between
the two transitions as possible.
Minimum mount height between range top to hood
bottom should be no less than 26”.
Maximum mount height should be no higher than
34”.
It is important to install the hood at the proper
mounting height. Hoods mounted too low could
UHVXOWLQKHDWGDPDJHDQG¿UHKD]DUGZKLOHKRRGV
mounted too high will be hard to reach and will
ORRVHSHUIRUPDQFHDQGHI¿FLHQF\
If available, also refer to range manufacturer’s
height clearance requirements and recommended
hood mounting height above range. Always check
your local codes for any differences.
Duct cover extension kit available for ceiling
heights up to 12 feet. Turn to page 19 for part
number and ordering information.
D
DAMAGE-SHIPMENT / INSTALLATION:
3OHDVHIXOO\LQVSHFWXQLWIRUGDPDJHEHIRUH
installation.
,IWKHXQLWLVGDPDJHGLQVKLSPHQWUHWXUQWKH
unit to the store in which it was bought for
repair or replacement.
,IWKHXQLWLVGDPDJHGE\WKHFXVWRPHUUHSDLU
or replacement is the responsibility of the
customer.
,IWKHXQLWLVGDPDJHGE\WKHLQVWDOOHULIRWKHU
WKDQWKHFXVWRPHUUHSDLURIUHSODFHPHQWPXVW
be made by arrangement between customer
and installer.
26” min.
34” max.
min. A
min. B
max. C
min. D
min. E
max. F
Standard
Extension
Hood Heights
Duct Cover
Duct Cove
r
minimum ducted (A) 27”
42“
minimum recirculating (B) 31”
46“
maximum (C) 50”
80”
Ceiling Heights
minimum ducted (D) 89” (7’ 5”)
104“ (8’ 8”)
minimum recirculating (E) 93” (7’ 9”)
108“ (9’)
maximum (F) 120” (10’) 150” (12’ 6”)
36”
Содержание Roma Wall ZRO-E30CS
Страница 2: ...www zephyronline com...
Страница 20: ...18 www zephyronline com Fan Curve Diagrams...
Страница 24: ...www zephyronline com...
Страница 28: ...Liste du mat riel 4 www zephyronline com ZRO E30CS ZRO M90CS ZRC 01RO...
Страница 42: ...18 www zephyronline com Diagrammes des courbes caract ristiques des ventilateurs...