ZS SPAN INSTALLATION MANUAL FOR RAIL-BASED APPLICATIONS - U.S.
Special Inset: Interlocks
Connect Array Skirt
Connect PV modules
Built-in tolerance for module size
variations and adjustability
The Interlock creates a simultaneous structural and electrical bond on both Key and Tongue sides.
Interlock
Array Skirt
How Interlocks Are Used
Interlock Timing and Alignment Marks
Gap OK
Down-roof
Part No. 850-1388
Timing mark for Zep
Tool
Key side
Tongue side
Used to align module edges
around center point
Center point
Interlock
Zep
Farthest allowable position
to align with module edge
when shifting Interlock
Note:
If the Key side of an Interlock
Zep is visible, the Interlock is positioned
too far to one side.
1/2” gap between
modules
3” total range
Interlock Positioning
Modules
Module gap must remain
between these marks