Страница 1: ...IWAC Display Access Controller with Display ZIO IWACD USER MANUAL ds kmfroi Application Program Version 1 1 User manual edition 1 1 _a www zennio com...

Страница 2: ...trol System 5 1 3 Installation 8 1 4 Start Up and power loss 10 2 Configuration 11 2 1 General 11 2 2 Inputs 14 2 2 1 Binary Input 14 2 2 2 Temperature Probe 14 2 2 3 Motion Detector 14 2 3 Buttons 16...

Страница 3: ...zennio com Technical Support http support zennio com 3 DOCUMENT UPDATES Version Changes Page s 1 1 _a Changes in the application program Update of the Heartbeat Binary Inputs Motion Detector and Temp...

Страница 4: ...pe MIFARE DESFire 2 4 inch OLED display with 128 x 64 pixels resolution Multilanguage Buzzer for an audible acknowledgement of user actions with the possibility of disabling it by object Encrypted com...

Страница 5: ...e Open command is correctly received from IWAC access granted Securel will release the lock for a while to open the door BMS Building Management System computer system that assumes the integral automa...

Страница 6: ...a specific group the identifier of the selected group will be recorded in the card This option only supports DESFire cards Associate the card with a specific IWAC Display the identifier of the IWAC D...

Страница 7: ...ist Card 2 Card 2 IWAC 245 Group Guest Card 3 Group Cleaning Card 4 Group Staff Card 1 Access granted Card 2 Access denied Card 3 Access denied Card 4 Access denied Card 1 Access denied Card 2 Access...

Страница 8: ...ll enter into safe mode In such case the LED will blink in red every 0 5 seconds Inputs 4 input ports for the insertion of the stripped cables of external elements such as switches motion detectors te...

Страница 9: ...tween both devices Figure 3 shows a connection diagram of IWAC Securel power supply and electric strike Figure 3 Access Control System connection diagram For detailed information about the technical f...

Страница 10: ...ted in Z Access to respond to the request For proper operation of the buttons it is recommended not to be pressing them during the initialization either after programming or after connecting the exter...

Страница 11: ...he left depending on whether the device will or will not be connected any external accessories See section 2 2 for details Buttons enables or disables the Buttons tab in the tree on the left depending...

Страница 12: ...e room status These objects are Room State Control 1 byte allows changing the room status The values available are 0 Normal 1 Make Up 2 Do Not Disturb Room State Make Up Room Status 1 bit indicates wh...

Страница 13: ...o the system the card is valid The following information is transmitted UUID of the card in ASCII format and also the most significant bit of the first character of the object is used to indicate whet...

Страница 14: ...o com 2 2 2 TEMPERATURE PROBE Please refer to the Temperature Probe user manual available under the IWAC Display product section at www zennio com 2 2 3 MOTION DETECTOR It is possible to connect motio...

Страница 15: ...ase refer specifically to the aforementioned user manual Motion detectors with references ZN1IO DETEC and ZN1IO DETEC N are not compatible with IWAC Display may report inaccurate measurements if conne...

Страница 16: ...t provided for this purpose All the buttons are identical this brings a high level of versatility for a wide variety of applications The following is a list of the functions that can be assigned to ea...

Страница 17: ...the user touches the button a binary value will be sent to the KNX bus This value is configurable and may be 0 or 1 or alternate with every touch according to the sequence 1 0 1 Hold Release as soon...

Страница 18: ...on to add a description to each button of the project The main parameter that needs to be configured is Function sets the desired function for the button Binary Hold Release Two Objects Short Press Lo...

Страница 19: ...tton Hold Release Action on Hold sets the value to be sent to the bus through Button n Binary Control Hold Release when the user touches the button The options are Send 0 and Send 1 default Action on...

Страница 20: ...Action on Long Press sets the value to be sent to the bus through Button n Two Objects Long press when the user long presses the button The options are the same as for the short press Long Press Thre...

Страница 21: ...characters supported in IWAC Display are Unicode U 0021 U 00FF refer to https www utf8 chartable de unicode utf8 table pl to see the character table for these codes ETS PARAMETERIZATION Figure 13 Disp...

Страница 22: ...ing and do not disturb It is possible to choose between two different icons for cleaning status Person Cleaning or Broom When in do not disturb status a lock is displayed Normal Do not disturb Cleanin...

Страница 23: ...nt that the main language is always enabled Select Language list of the available languages Language X enables or disables the additional language X Select Language list of the available languages to...

Страница 24: ...ure 17 Display Texts The screen is divided into three zones Message When Access Is Granted Message When Access Is Denied Message When Access Is Granted DND Active Parameters Line 1 and Line 2 permit s...

Страница 25: ...he following parameters Security Parameters System ID this value shall be common for all IWAC Display in the installation It is an essential part of the communication security Device ID this value sha...

Страница 26: ...ate Is Do Not Disturb sets the action to perform when a group with access permission tries to access to a room in Do Not Disturb status This action only applies to the groups the guests of the room ca...

Страница 27: ...ch 0 1 Button x Binary Control 0 1 Bit Generic Control 1 Bit O C T R DPT_Switch 0 1 Button x Binary Control 1 1 Bit Generic Control 1 Bit O C T R DPT_Switch 0 1 Button x Binary Control 0 1 1 Bit Gener...

Страница 28: ...by 1 0x8 Stop 0x9 Inc by 100 0xF Inc by 1 Ix Short Press Brighter Darker Switch Bright Dark 1 Bit C T DPT_Switch 0 1 Ix Short Press Light On Sending of 1 On 1 Bit C T DPT_Switch 0 1 Ix Short Press Lig...

Страница 29: ..._Dimming 0x0 Stop 0x1 Dec by 100 0x7 Dec by 1 0x8 Stop 0x9 Inc by 100 0xF Inc by 1 Ix Long Press Brighter Darker Long Pr Brighter Darker Release Stop 1 Bit C T DPT_Switch 0 1 Ix Long Press Light On Se...

Страница 30: ...resence Waiting Time 0 65535 s 39 68 2 Bytes I C W DPT_TimePeriodSec 1 65535 Ix Presence Listening Time 1 65535 s 40 69 1 Bit I C W DPT_Enable 0 1 Ix Presence Enable According to parameters 41 70 1 Bi...