EyeZen TP
Motion detector with luminosity sensor
for ceiling mounting
ZPDEZTP
U
S
E
R
M
A
N
L
Application program version: [1.3]
User manual edition: [1.3]_a
www.zennio.com
Страница 1: ...EyeZen TP Motion detector with luminosity sensor for ceiling mounting ZPDEZTP USER MANUAL Application program version 1 3 User manual edition 1 3 _a www zennio com...
Страница 2: ...ort http support zennio com 2 CONTENTS Contents 2 1 Introduction 3 1 1 EyeZen TP 3 1 2 Installation 4 1 3 Start Up and Power Loss 5 2 Configuration 6 2 1 General 6 2 2 Presence Detector 8 2 3 Logic Fu...
Страница 3: ...e sensitivity LED to indicate motion Two types of lenses black and white Presence detection 6 presence detection channels Luminosity dependent presence detection optional Periodic and delayed sendings...
Страница 4: ...n this button sets the device into the programming mode making the associated LED 4 light in red Note if this button is held while plugging the device into the KNX bus the device will enter the safe m...
Страница 5: ...start up of the device the detection notification LED flashes red for one minute before the motion sensor is ready Depending on the configuration some specific actions will also be performed during th...
Страница 6: ...ence Detection enabled 1 enables the Presence Detector tab in the tree on the left For more information see section 2 2 Logic Functions enabled disabled enables or disables the Logic Functions tab in...
Страница 7: ...ennio com Technical Support http support zennio com 7 Note the first sending after download or bus failure takes place with a delay of up to 255 seconds to prevent bus overload The following sendings...
Страница 8: ...ether a particular space is under occupation no matter if the occupant moves or not i e no matter if the device is detecting presence in the room or not It also allows setting different luminosity set...
Страница 9: ...m Technical Support http support zennio com 9 Figure 4 Presence Detector Configuration Lens Type White Black Selecting the lens type that EyeZen TP has installed will allow a correct measurement of lu...
Страница 10: ...n of each function can depend on a configurable condition which will be evaluated every time the function is triggered through specific parameterisable communication objects The result after executing...
Страница 11: ...ht 1 Bit I C W DPT_DayNight 0 1 Day Night 0 Night 1 Day 11 1 Bit I C W DPT_Enable 0 1 Detection LED 0 Disable 1 Enable 1 Bit I C W DPT_Enable 0 1 Detection LED 0 Disable 1 Enable Only During the Day 1...
Страница 12: ...tion 0 1 Motion detected by an external sensor 86 102 1 Bit I C W DPT_Enable 0 1 CLCx Lock Status 0 Unlock 1 Lock 1 Bit I C W DPT_Enable 0 1 CLCx Lock Status 0 Lock 1 Unlock 87 103 1 Bit I C W DPT_Swi...
Страница 13: ...Byte Data Entry 0 255 182 183 184 185 186 187 188 189 190 191 192 193 194 195 196 197 2 Bytes I C W DPT_Value_2_Ucount 0 65535 LF 2 Byte Data Entry x 2 Byte Data Entry DPT_Value_2_Count 32768 32767 9...
Страница 14: ...n and send us your inquiries about Zennio devices http support zennio com Zennio Avance y Tecnolog a S L C R o Jarama 132 Nave P 8 11 45007 Toledo Spain Tel 34 925 232 002 www zennio com info zennio c...