Page 4-2
Replacement Tests
WARNING : Wh e n t he l i n e c o rd i s c o n n e c ted to a n
A C outlet, hazardous voltages can be present in si d e
the computer.
R efer to I l l u s tr ation B o ok , Page 3, Pi ct orial 4- 1 f o r
the following steps.
•
Un p l u g t h e l i n e cord from the AC outle t.
•
Carefully r em ove all cables from the rear of the
it aside.
•
C arefully l i f t t h e t o p c a s e straight u p a n d s e t
Computer.
slide, Set the rubber plugs aside.
•
Carefully p ul l th e rubber plug out of each metal
R efer to I l l u s t r ation B o ok , Page 4, Pi c t o r ial 4- 2 f o r
the follow in g steps.
•
L ocate the p o w e r s u p p l y a n d l o o k f o r a n u n -
connected cable and plug labeled P6 (not P3),
a s shown in the inset draw i n g .
I f you f i n d t h i s u n c o n n e cted c a b le, yo u w i l l
n ot have to replace the power supp l y .
If your power sup pl y d oes not have this uncon -
n ected cable an d p l u g , y o u m u s t r e p l ac e t h e
power supply.
•
U se a small f l at-blade screwd r i ver to m ov e th e
m etal sl i des all t h e w a y t o w a r d t h e f r o n t a n d
then '/4" toward the back as shown.