background image

Page 1 of 8

81424NZ June 2012 v1.01

Installation and Operating Procedures

Aqua Sense Taps

Automatic Taps - Deck and Wall Models.

AquaSense taps are suitable for use in Ablution troughs; Basins and Kitchen sinks

Wall installation model

Deck installation model

Wall Mounted (battery) Model Code:  42226NZ (Surgeon)        

Wall Mounted (mains) Model Code:    42225NZ (Surgeon)

Deck Mounted (battery) Model Code: 42211NZ

Deck Mounted (mains) Model Code:  42208NZ

Wall Mounted (battery) Model Code:  42222NZ    

Wall Mounted (mains) Model Code:    42223NZ

High Neck  (battery) Model Code:       42229

Note: Surgeon models have a 20 second run-on after use. 

High Neck model

Содержание Surgeon 42226NZ

Страница 1: ...ks Wall installation model Deck installation model Wall Mounted battery Model Code 42226NZ Surgeon Wall Mounted mains Model Code 42225NZ Surgeon Deck Mounted battery Model Code 42211NZ Deck Mounted mains Model Code 42208NZ Wall Mounted battery Model Code 42222NZ Wall Mounted mains Model Code 42223NZ High Neck battery Model Code 42229 Note Surgeon models have a 20 second run on after use High Neck ...

Страница 2: ...onents 4 Installation Details 4 5 Trouble Shooting 6 Maintainence 6 End of Disposal 6 Warranty Information 8 NOTE It is the installers responsibility to ensure the installation complies with AS NZS3500 1 AS NZS3500 2 AS NZS3500 4 1 AS NZS3500 4 2 and local water authority regulations Contents ...

Страница 3: ...l The sensing distance for standard wall mounted tap is 150mm or 200mm for the surgeon s model To prevent any nuisance sensing keep a 100mm distance from sink base to Sensing Range lowest point see fig 1 and fig 2 Secure the faucet with the nut and clamps provided Important where ever possible you must use the base fixing pins supplied with the faucet Ensure the flow restrictor in the tap outlet i...

Страница 4: ...le hose Tap connection NOT SUPPLIED 1 Isolation valve 2 Double check valve 3 Mixing valve optional 4 In line filter Outlet to Tap Wall installation detail Deck installation detail Important installation details for wall mount taps to avoid reflection problems Clinical Basins 150 200mm Scrub Troughs 250mm 300mm Recommended Distance The minimum recommended distance from the tap spout to the sink bas...

Страница 5: ... power supply unit The use of an alternative unit may cause damage TAP1 TAP2 TAP3 Installation details Power specifications Input 220 240 V AC Current 0 3 A Freq 50 60 Hz Output 6 V DC Instructions for Attaching Colour Coded Sticker on AquaSense Tap Attach Colour Coded Temperature Sticker at the front face of the Tap s spout NOTE Plumber must attach the appropriate colour coded sticker compliant t...

Страница 6: ...his product correctly Please contact your local city council for collection centre details End of Life Disposal Maintenance Replacement rubber for diaphragm Valve Diaphragm Replacement Isolate power and water supply Remove fixing clip on top of latching valve coil by levering up clip with screw driver and clicking back until clip releases from shaft Lift coil spring clip and spacer from latching v...

Страница 7: ...Page 7 of 8 81424NZ June 2012 v1 01 This page intentionally left blank ...

Страница 8: ...ement 50 rrp AutoBoil Parts Labour Parts only replacement 25 rrp Commercial HydroTap Parts Labour Parts only All other Parts Labour Warranty table effective from 1st April 2008 Full warranty details may be found on the website Registering Your Purchase Registering your Zenith installation on the website may help to establish date of installation should it become necessary to service the appliance ...