4
EA1400/1600 Installation & User Manual
A100K11939
2
Connectors and Controls
Figure 1: Amplifier Front Panel
Figure 2: Amplifier Rear Panel
2.1. Cabinet
The amplifier is prepared for mounting in a standard 19” rack and will occupy 2HU in height. The amplifier
can also be free-standing on a level, open surface. The amplifier has a built-in cooling fan but the front and
back must be kept free of objects in order to secure sufficient air flow.
2.2. Power
The amplifier is powered by 100-240 VAC 50/60 Hz mains. There is a mains circuit breaker on the cabinet
rear side, and a mains fuse on the Main Board inside the cabinet. The fuse value is 8A. The amplifier must
be grounded with the main cable, or with a 2.5 mm
2
wire between the amplifier’s ground terminal and a
proven good PE grounding point.