Warnings 

 

This manual should be read in conjunction with the ZENER 8000 Installation Manual (IM00124). 
 

Read  all  operating  instructions  before  installing,  wiring,  operating,  servicing  or  inspecting  the 
High Performance Output Filter. Ensure that the instruction manual is made available to the final 
user of the product as well as all personnel involved in any aspect of installation, adjustment or 
maintenance.  Your  High Performance  Output  Filter must  be  applied  and  installed  by  a  suitably 
qualified  and  experienced  electrical  tradesperson  in  accordance  with  this  manual,  good 
engineering practice and all local rules and regulations 

 

 

There are hazardous voltages inside the High Performance Output Filter whenever it is connected 
to an electrical supply and for some time after it is disconnected. Before touching anything inside 
the  High  Performance  Output  Filter  enclosure  or  other  equipment  connected  to  the  High 
Performance Output Filter terminals, disconnect all sources of electrical power, wait at least 11 
minutes for capacitors within the High Performance Output Filter to discharge to less than 50VDC 
and then ensure, by measurement, that there is no hazardous AC or DC voltage present at any 
terminal. 

 

The High Performance Output Filter contains high energy circuits that may be hazardous. Do not operate the High 
Performance Output Filter with the door open or any part of the enclosure removed. 

Do not touch the terminals of the High Performance Output Filter or any associated motor and wiring when it is 
energised, even if the High Performance Output Filter and motor are stopped. Electric shock may result. 

Do not modify this equipment electrically, mechanically or otherwise. Modification may create safety hazards. 

The High Performance Output Filter is designed to operate in series with an appropriately rated and otherwise 
suitable 3 phase induction motor. It is not suitable for single phase motors or other types of motor or non-motor 
load. Use with inappropriate load types may create a safety hazard. 

Where the High Performance Output Filter is used as a component part of another product, it is the purchaser’s 
responsibility to ensure that the final product meets all of the necessary safety, EMC, regulatory, operational and 
other requirements for that product. Requirements for the purchaser’s final product may be substantially different to 
the requirements for stand-alone filters. 

The High Performance Output Filter is intended for use only in fixed wiring applications. It is not intended for use on a 
flexible supply cable. 

Mount the High Performance Output Filter on a vertical, incombustible surface such as metal or masonry. 

Do not place combustible or flammable material near the High Performance Output Filter. Failure to observe these 
precautions may create a fire hazard. 

The High Performance Output Filter is manufactured under strict quality control arrangements, however additional 
and independent safety equipment must be installed if the application is such that failure of the product may result in 
personal injury or property damage. 

Ensure that electrical noise generated by the product and any associated equipment does not adversely affect the 
proper operation of other equipment or systems, particularly those that have a safety function. 

Do not install this equipment in locations where mechanical damage to the enclosure is possible. In particular, 
consider vehicles, vandalism and attack by insects or animals. Severe equipment damage and safety hazards may 
result.  

 

 

Содержание IP00 Series

Страница 1: ...ZENER VARIDRIVE SOLUTIONS ZENER 8000 High Performance Output Filter IP00 Series Instruction Manual Document IM00168 Printed 18 March 2019...

Страница 2: ...rated in a safe manner It is the responsibility of the user to ensure compliance with all regulations and practices covering the installation and wiring of your ZENER 8000 The instruction manual shoul...

Страница 3: ...s Explanation of Symbols 1 Receiving 1 Warnings 2 Performance 3 Mechanical Installation Information 4 Dimensions 4 Installation Considerations 5 Operating Considerations 5 Wiring Diagram 6 B Terminal...

Страница 4: ......

Страница 5: ...a common error in installation commissioning or operation Receiving Inspect the High Performance Output Filter for any shipping damage If any damage is found report it to the carrier immediately Acces...

Страница 6: ...ment electrically mechanically or otherwise Modification may create safety hazards The High Performance Output Filter is designed to operate in series with an appropriately rated and otherwise suitabl...

Страница 7: ...igh efficiency greater than 99 Eliminate the need for installing screened motor cables The permissible cable length1 between filter and motor is 500m Categories as defined in AS61800 3 are C1 limits a...

Страница 8: ...x B X C Weight Mounting holes AHP0070 200 x 280 x 150 10 kg AHP2200 650 x 335 x 410 14mm Diameter 600mm x 250mm centres AHP3150 AHP3900 AHP4900 130 kg C A B Allow sufficient clearance for all cable t...

Страница 9: ...ions may be required for all enclosure types The installation location and environment should provide for safe access and working conditions for service personnel Do not mount the High Performance Out...

Страница 10: ...rnal trip input of the ZENER 8000 i If the High Performance Output Filter is not mounted adjacent to the inverter on the same mounting panel inside a metal enclosure screened power cable may be requir...

Страница 11: ...for the protective earth conductor in the inverter installation Chassis A B models or 30A for models Chassis C D fitted with a fused terminal For supply protection cable size and electrical isolation...

Страница 12: ...AHP3900 390A 429A AHP4900 490A 539A 630W Operation at higher Audible Frequency or at speeds 50Hz may require derating The filter is matched to the ZENER 8000 to allow for operation at temperatures ab...

Страница 13: ......

Страница 14: ...IMITED ACN 001 595 428 366 Horsley Rd Milperra NSW 2214 Australia PO Box 347 Milperra NSW 2144 Australia T 61 2 97953600 E sales zener net http www zener com au Zener Electric Pty Limited 2019 IM00168...

Отзывы: