background image

Zen One Height Adjustable Standing Desk

Programming Guide

Operation Instructions

1. Power on

When the system is powered on, you will hear a beep and the existing desktop height will be displayed on the 
controller.

2. Upward and downward movement 

Press the “    “ or “     “ and do not release until the desk reaches the desired height. If the motor continuously 
operates for a relatively long period of time the overheat protection will activate. The control panel will work 
normally again after approximately 20 minutes.

3. Memory Mode 

To store your preferred heights in the controller’s memory, first press “M”. The letter “S-” will be displayed. Now 

press 1, 2 or 3 within 5 seconds to store the current height in memory. The 1, 2 or 3 buttons can each store a 

different height. Once the height has been stored in the memory, you can select any of the 3 height settings by 

pressing the corresponding button. Pressing any other button (except for “T”) will stop the automatic adjustment.

4. Reset Mode

While the unit is powered on, press the ”     ” button until the desk moves into a fully lowered position, “62.0” 

or “63.0” or “73.0” is displayed on the controller. Again, press the “     ” button until “RST” is displayed on the 

controller. Once the display shows “61.0” or “62.0” or “72.5”, release the “     ” button, the desk will move upward 

for approximately 10mm or 5mm and automatically come to a stop. After finishing the reset, the controller should 

display “62.0” or “63.0” or “73.0” which is the current height. You may need to complete this process when you first 

set up your desk to ensure proper function

5. Time Reminder

To set the time reminder, press” T “found on the controller. The display will flash “0.5h” which means 0.5 hour. Press 

the” T “ repetitively to increase 0.5 hours at a lime. The maximum timer setting is two hours. The timer is set when 

the digit stops flashing and the light in the top right corner of the controller is on. When the timer has reached the 

set time, the buzzer beeps, reminding the user to adjust his/her working position. Once a timer setting has expired, 

the unit’s timer is cancelled. To de-activate the timer, press the “T” five times until the current height is displayed 

and the light found in the upper right side of the controller is off.

6. Switch measurement unit

The preset measurement shown on the display is cm. If you would like to change cm to inch, please restart the 

system and press the button “ T “ for 8 seconds. After the buzzer beeps twice, the measurement is successfully 

reset. If you would like to switch inch back to cm, please restart the system and press the button “ T” for 8 seconds. 

After the buzzer beeps once, the system is successfully switched to cm measurement again.

Upward movement

Downward movement

Memory 1 / 2 / 3

Memory

Timer

Display