Humphrey Field Analyzer II-
i
series User Manual
2660021145640 A
Database Management
11-3
On the Additional Setup Menu
Copies Custom Test Patterns, Main Menu button definitions, network settings, and System Setup
selections to a USB storage device.
Reinstates Custom Test Patterns, Main Menu button definitions, network settings and System Setup
selections from the backup configuration floppy disk or USB storage device.
Note: Network settings will only be restored to the same HFA II-
i
from which they were
backed up.
A database repair utility; used only in the event of hard disk database problems.
A database repair utility; used only in the event of USB storage device or floppy disk database
problems.
Deletes files containing patient data with no associated test data.
Patient Database Protection Procedures
Creating alternate copies of your patient database is important, but can be a lengthy procedure.
Therefore, Carl Zeiss Meditec recommends that you choose a schedule that suits your office,
preferably one that does not interfere with patient care and testing. Whether you perform 25 visual
field tests each week or five, every test worth saving (whether to a USB storage device, hard disk,
network file server, or floppy disk) is worthy of being protected by being maintained on alternate
storage media. In the event of database failure, alternate copies of your database can be used as a
back up measure to minimize or eliminate data loss.
The removable storage media used with the HFA II-
i
(USB storage devices and/or floppy disks) are
not indestructible. Improper care and handling will affect the contents and render the media
unusable. Floppy disks also have a limited shelf life and should not be used indefinitely. It is
advisable to rotate between at least two sets of storage media. Information on the proper care and
handling of storage media is covered at the end of this section, as well as in
Database Protection
Your HFA II-
i
comes equipped with five USB ports for connecting USB storage devices. You may have
licensed the HFA-NET Pro networking software on your HFA. An optional USB floppy disk drive is
also available. These different backup media afford owners several alternative methods for backing
up their hard disk data.
Note: An optional USB floppy disk drive should only be used for backwards compatibility. It is highly
recommended to use USB storage devices instead of floppy disks. Floppy disks may not be available
in the near future.
The recommended database protection procedure for your HFA II-
i
involves the following steps:
Содержание Humphrey II-i series
Страница 1: ...User Manual Humphrey Field Analyzer II i series System Software Version 5 1...
Страница 8: ...Humphrey Field Analyzer II i series User Manual 2660021145640 A vi...
Страница 40: ...Introduction Instrument Setup Humphrey Field Analyzer II i series User Manual 2660021145640 A 1 32...
Страница 74: ...General Operation Humphrey Field Analyzer II i series User Manual 2660021145640 A 2 34...
Страница 130: ...Testing Humphrey Field Analyzer II i series User Manual 2660021145640 A 5 20...
Страница 158: ...STATPAC Analysis Printing Humphrey Field Analyzer II i series User Manual 2660021145640 A 7 22...
Страница 338: ...Kinetic Testing Humphrey Field Analyzer II i series User Manual 2660021145640 A 13 62...
Страница 412: ...Care and Cleaning Humphrey Field Analyzer II i series User Manual 2660021145640 A 15 14...
Страница 416: ...Product Specifications Humphrey Field Analyzer II i series User Manual 2660021145640 A A 4...
Страница 420: ...Product Features Humphrey Field Analyzer II i series User Manual 2660021145640 A B 4...
Страница 428: ...Icon Glossary Humphrey Field Analyzer II i series User Manual 2660021145640 A D 2...
Страница 540: ...Installing Licensing HFA II i Software Humphrey Field Analyzer II i series User Manual 2660021145640 A J 10...
Страница 558: ...Reference to Older Test Strategies Humphrey Field Analyzer II i series User Manual 2660021145640 A L 10...
Страница 579: ......