background image

 

PRODUCT DESCRIPTION 

Carl Zeiss 

Compatible Objectives for use with Auto Focus 

Auto Focus equipment 

 
 

 

14 

425131-7044-001 

06/2013 

Series 

Objective 

Item number 

EC Epiplan-

Neofluar 

EC Epiplan-Neofluar 1.25x/0.03 M27 

422310-9900-000 

EC Epiplan-Neofluar 2.5x/0.06 M27 

422320-9900-000 

EC Epiplan-Neofluar 2.5x/0.06 HD M27 

422320-9960-000 

EC Epiplan-Neofluar 2.5x/0.06 HD M27 

422322-9960-000 

EC Epiplan-Neofluar 2.5x/0.06 M27 

422322-9900-000 

EC Epiplan-Neofluar 2.5x/0.06 Pol 

442313-9902-000 

EC Epiplan-Neofluar 2.5x/0.06 Pol M27 

422323-9900-000 

EC Epiplan-Neofluar 5x/0.13 DIC M27 

000000-1156-511 

EC Epiplan-Neofluar 5x/0.13 HD DIC M27 

000000-1156-514 

EC Epiplan-Neofluar 5x/0.13 Pol 

442323-9901-000 

EC Epiplan-Neofluar 5x/0.13 Pol M27 

000000-1156-512 

EC Epiplan-Neofluar 5x/0.13 HD M27 

422330-9960-000 

EC Epiplan-Neofluar 10x/0.25 HD M27 

422340-9960-000 

EC Epiplan-Neofluar 10x/0.25 DIC M27 

422342-9900-000 

EC Epiplan-Neofluar 10x/0.25 Pol 

442333-9901-000 

EC Epiplan-Neofluar 10x/0.25 Pol M27 

422343-9900-000 

EC Epiplan-Neofluar 10x/0.25 HD DIC M27 

422342-9960-000 

EC Epiplan-Neofluar 20x/0.50 HD M27 

422350-9960-000 

EC Epiplan-Neofluar 20x/0.5 DIC M27 

000000-1156-521 

EC Epiplan-Neofluar 20x/0.5 HD DIC M27 

000000-1156-524 

EC Epiplan-Neofluar 20x/0.5 Pol 

000000-1170-667 

EC Epiplan-Neofluar 20x/0.5 Pol 

000000-1156-522 

EC Epiplan-Neofluar 50x/0.80 HD M27 

422370-9960-000 

EC Epiplan-Neofluar 50x/0.8 DIC M27 

000000-1156-527 

EC Epiplan-Neofluar 50x/0.8 HD DIC 

000000-1156-528 

EC Epiplan-Neofluar 50x/0.8 Pol 

000000-1170-666 

EC Epiplan-Neofluar 50x/0.8 Pol 

000000-1156-526 

EC Epiplan-Neofluar 50x/1.0 Oil Pol 

422373-9900-000 

EC Epiplan-Neofluar 100x/0.90 HD M27 

422390-9960-000 

EC Epiplan-Neofluar 100x/0.90 DIC M27 

422392-9900-000 

EC Epiplan-Neofluar 100x/0.90 HD DIC 

422392-9960-000 

EC Epiplan-Neofluar 100x/0.90 HD DIC 

442385-9902-000 

EC Epiplan-Neofluar 100x/0.90 Pol 

442383-9903-000 

EC Epiplan-Neofluar 100x/0.90 Pol M27 

422393-9900-000 

LD EC Epiplan-
Neofluar 

LD EC Epiplan-Neofluar 20x/0.22 DIC M27 

422452-9900-000 

LD EC Epiplan-Neofluar 20x/0.22 HD DIC M27 

422452-9960-000 

LD EC Epiplan-Neofluar 50x/0.55 DIC M27 

422472-9900-000 

LD EC Epiplan-Neofluar 50x/0.55 HD DIC M27 

422472-9960-000 

LD EC Epiplan-Neofluar 100x/0.75 DIC 

000000-1156-532 

LD EC Epiplan-Neofluar 100x/0.75 HD DIC M27 

000000-1156-538 

Table 1 

Compatible objectives for use with Auto Focus 

Содержание Auto Focus

Страница 1: ...Operating Manual Auto Focus equipment...

Страница 2: ......

Страница 3: ...approval to do so has been obtained Offenders will be held liable for the payment of damages All rights including rights created by patent grant or registration of a utility model or design are reserv...

Страница 4: ...17 2 7 2 Ambient conditions 17 2 7 3 Operating data 18 3 INSTALLATION 19 3 1 Connecting Auto Focus 19 3 2 Camera deflection 21 3 3 Auto Focus objectives 21 3 4 Insert damping filter 21 4 OPERATION 22...

Страница 5: ...CONTENTS Auto Focus equipment Carl Zeiss 06 2013 425131 7044 001 5 5 5 Other fault events 35 5 6 Service 36 6 INTELLECTUAL PROPERTY 37 7 INDEX 38...

Страница 6: ...module 20 Fig 7 Rear view of controller and connections 20 Fig 8 Manual camera deflection 425103 0000 000 for left side port 21 Fig 9 Front view of controller 22 Fig 10 TFT display Home screen with Au...

Страница 7: ...rries a mark This operating manual contains information and warnings that must be followed by the owner operator personnel The warnings and advisory notes used throughout this operating manual have th...

Страница 8: ...ift fuses and shorting of fuse holders is prohibited The manufacturer cannot accept liability if the device or individual assemblies or parts thereof have been used for any other purpose The same will...

Страница 9: ...ntroller is designed to work within a voltage range of 100 V to 240 V 10 at 50 to 60 Hz without additional voltage conversion Voltage to the Axio Imager 2 is supplied from the separate internal power...

Страница 10: ...ed in cases of natural wear in particular wearing parts or improper handling The manufacturer will refuse any liability for damage resulting from incorrect operation negligence or unauthorized interve...

Страница 11: ...should be taken into consideration for the different objective magnifications These differ depending on the system configuration work mode and sample surface The maximum capture range of Auto Focus se...

Страница 12: ...ection side port left manual 425103 0000 000 or successor or camera deflection side port left motorized 425104 0000 000 or successor The following firmware and software versions or newer versions are...

Страница 13: ...422050 9902 000 EC Epiplan 20x 0 4 H M27 422050 9903 000 EC Epiplan 20x 0 4 HD M27 422050 9960 000 EC Epiplan 20x 0 4 HD M27 422050 9961 000 EC Epiplan 40x 0 6 M27 422060 9901 000 EC Epiplan 40x 0 6 H...

Страница 14: ...20x 0 50 HD M27 422350 9960 000 EC Epiplan Neofluar 20x 0 5 DIC M27 000000 1156 521 EC Epiplan Neofluar 20x 0 5 HD DIC M27 000000 1156 524 EC Epiplan Neofluar 20x 0 5 Pol 000000 1170 667 EC Epiplan N...

Страница 15: ...Focus varies depending on the type of objective the objective magnification and the optical characteristics of the sample The positioning accuracy and the speed of the Auto Focus vary depending on th...

Страница 16: ...tails can be found in section 4 2 on page 23 Changes in the focus position are registered by the sensor with any deviations being automatically compensated by the direct access of the controller to th...

Страница 17: ...ensor module ca 1300 g Controller ca 4800 g 2 7 2 Ambient conditions Transportation in packed state Permissible ambient temperature 40 C to 70 C Storage Permissible ambient temperature 5 C to 40 C Per...

Страница 18: ...DIN EN 61326 1 Line input voltage 100 V AC to 240 V AC 10 No line voltage conversion required Line frequency 50 60 Hz Power consumption max 80 VA Fuses according to IEC 60127 fc12 focus controller T...

Страница 19: ...0 000 or successor An Axio Imager 2 Axio Imager Vario stand with motorized Z axis drive focusing objective turret is required in order to operate Auto Focus Retrofitting to existing older Axio Imager...

Страница 20: ...left side camera deflection Connect the Auto Focus to the controller To do so insert the Firewire cable into the connections of the Auto Focus Fig 6 2 and the controller Fig 7 4 Then insert the contro...

Страница 21: ...ntered manually via the TFT display MTB This helps ensure that the magnification factor reference number is stored and that the focus position can be correctly calibrated via the TFT or the MTB for th...

Страница 22: ...extension socket Once power is available the control programs of the Auto Focus and the microscope will start automatically and communication between the two programs will be established via the CAN...

Страница 23: ...the Options button It is important to follow the instructions for setting up the Auto Focus given in section 4 8 on page 31 Setting focus reference values First press the Microscope button on the TFT...

Страница 24: ...cycles is shown in the Period field To change the period press the Period button Select or redefine period Fig 12 The period can be selected using pre defined periods continuous 1 s 2 s 5 s etc or ca...

Страница 25: ...inadvertent adjustment of the focus and therefore the creation of an offset See also section 4 3 page 27 Focusing is carried out entirely by the Auto Focus if activated Resolution and Speed The Exact...

Страница 26: ...afer structured Reflective Partially reflective Thin film solar cells Partially reflective Diffuse TFT displays Reflective Metallographic sample Reflective Partially reflective Semiconductor masks Ref...

Страница 27: ...Auto Focus Standby Turn off the Auto Focus the Auto Focus is now in standby mode Once Perform one Auto Focus search Cancel Cancel the Auto Focus search Auto Focus options Options Call up change the Au...

Страница 28: ...ctive and be sufficiently reflective See also Table 3 on page 26 Surface of sample and recommended settings The two statuses Working Standby are shown by a variable status icon Fig 14 on the TFT displ...

Страница 29: ...status The LED is turned off within a period Working xx s status or in Standby status A Z offset can be set manually in the On status using the focus wheel the TFT Display or the imaging software Axi...

Страница 30: ...used upon If the Work Load by AF option is selected the Work Load run is slower than if it is deactivated With the Axio Imager Vario it is also important to note that the focal plane must be within th...

Страница 31: ...nce values of individual objectives can be deleted from the user list by using the Reset button in the MTB This deletes the objective currently in use from the user list The deleted values are removed...

Страница 32: ...2 Replacement of fuses in the fc12 Auto Focus controller Make sure the power cable is disconnected before changing any fuses In the event of a fuse failure the cause must be identified and a possible...

Страница 33: ...isplay Has a sample actually been inserted and a typical region on the sample been selected Shift to a different XY position of the sample Pronounced irregularities scratches on the sample may result...

Страница 34: ...r reconfiguration when using the Auto Focus again for the first time Cable connection interrupted Reactivate the Auto Focus If the cable connection was interrupted Shut down the Auto Focus and the mic...

Страница 35: ...Auto Focus signal from being detected The Auto Focus starts to jump between two planes when moving the sample The structure being focused upon may be parallel to the signal structure of Auto Focus Rot...

Страница 36: ...t be performed by anyone other than Zeiss Customer Service experts or specially authorized technicians To request service please contact your regional representative office or For additional informati...

Страница 37: ...INTELLECTUAL PROPERTY Auto Focus equipment Carl Zeiss 06 2013 425131 7044 001 37 6 INTELLECTUAL PROPERTY The products device parts and procedures described in this manual are protected by patent law...

Страница 38: ...NDEX Page C Copyright 3 D Dimensions 17 E Error messages 34 G General view of components 12 I Installation 19 Instrument care 32 N Notes regarding operational safety 7 O Operation 22 P Product descrip...

Отзывы: