background image

10 

1. General 

 

1.1 Application 

 

This operating instruction is valid for the waste water lifting unit type E-ZW. 
Non-compliance with the operating instructions - in particular with the safety instructions - as well as non-manufacturer modification or use 
of non-original spare parts will result in loss of guarantee coverage. The manufacturer accepts no liability for damage or injury resulting from 
incorrect use of the equipment. 
These dewatering pumps are designed for delivering of well contaminated water with particulate materials from private household, industry 
and agriculture. The particle size must not exceed the mentioned size at ch. 1.3. 
This product may also pass as any other electrical equipment in cause of lacking electrical supply. If you may get any damages thereby, 
please calculate in accordance to the use an emergency power generator, a second pump and/ or a network independent alarm system. As the 
manufacturer we will be at your disposal after the buying for near information. In cause of defects or damages please contact your retail 
trader. 

 
Manufacturer

ZEHNDER Pumpen GmbH 

 

 

Zwönitzer Straße 19 

 

 

08344 Grünhain-Beierfeld 

 
Instruction last modified

: 03/2017 

 
 

1.2 Queries and Ordering 

 
For queries and orders please contact your authorised retail trader. 

 
 

1.3 Technical data 

 

Typ: 

E-ZW 50 A-2 

E-ZW 65 A 

E-ZW 80 A 

Input power P

1

 

380 W 

850 W 

850 W 

Motor power P

2

 

210 W 

430 W 

430 W 

Voltage / frequency 

230 V / 50 Hz 

Nominal current 

1.8 A 

3.7 A 

3.7 A 

Nominal speed 

2800 U/min 

Power cable 

10 m, 3 x 1 mm² 

max. capacity 

7,500 l/h 

9,500 l/h 

10,000 l/h 

max. head 

7,5 m 

14 m 

9 m 

max. particle size 

10 mm 

10 mm 

30 mm 

Pressure size 

G 1 1/4“ IG 

Weight 

6,5 kg 

8,0 kg 

9,0 kg 

Height over all 

340 mm 

358 mm 

372 mm 

Diameter 

175 mm 

max. liquid temperature 

40 °C (temporary

 

90 °C) 

max. dive in depth 

5 m 

Float switch 

yes 

 

Materials 

 
Pump body 

 

PP 

 

 

Impeller   

 

PA 6 

Outer housing 

 

Stainless steel 

 

Float switch 

 

PP 

Strainer   

 

Stainless steel 

 

Screws   

 

Stainless steel 

Motor housing 

 

Stainless steel 

 

Seals 

 

 

Carbon/ Ceramics 

Motor shaft 

 

Stainless steel 

 

Characteristics

 

 
 
 
 
 
 
 
 
 
 
 
 

GB

Содержание E-ZW series

Страница 1: ...Edelstahl Tauchpumpe Submersible pump stainless steel Pompe submersible E ZW EZW A EZW KS Betriebsanleitung Operating Instructions Manuel d utilisation GB F D...

Страница 2: ...rung Hersteller ZEHNDER Pumpen GmbH Zw nitzer Stra e 19 08344 Gr nhain Beierfeld Produktbezeichnung Tauchmotorpumpe Typenkennzeichnung E ZW 50 A 2 E ZW 65 E ZW 80 Technische Daten Nennspannung 230 V...

Страница 3: ...Pumpen GmbH Zw nitzer Stra e 19 08344 Gr nhain Beierfeld Stand der Betriebsanleitung 03 2017 1 2 Anfragen und Bestellungen Anfragen und Bestellungen richten Sie bitte an Ihren Fach bzw Einzelhandel 1...

Страница 4: ...ung Inspektion und Montage mu die entsprechende Qualifikation f r diese Arbeiten aufweisen Verantwortungsbereich Zust ndigkeit und die berwachung des Personals m ssen durch den Betreiber genau geregel...

Страница 5: ...ieferten Anlage ist nur bei bestimmungsm iger Verwendung entsprechend Abschnitt 1 Allgemeines der Betriebsanleitung gew hrleistet Die im Datenblatt angegebenen Grenzwerte d rfen auf keinen Fall bersch...

Страница 6: ...en frostfreien und dunklen Ort Die Motorwelle ist bei l ngerem Stillstand der Pumpe aller 2 Monate z B durch kurzes Einschalten der Pumpe zu drehen um ein Verkleben der Gleitringdichtung zu vermeiden...

Страница 7: ...verstopft oder verschlissen Reinigen Austauschen Druckleitung verstopft Schlauch geknickt Reinigen Knickstellen entfernen Bodensieb verstopft Reinigen 3 F rdermenge zu gering Pumpe ist nicht richtig e...

Страница 8: ...0 032 150 032 150 032 290 2 Kabelverschraubung PG 11 Ms 200 124 200 124 200 124 300 4 Ejot Schraube PT KA 40x10 WN 1412 800 030 800 030 800 030 301 4 Flachdichtung 8 5x3 3x1 0 100 911 100 911 100 911...

Страница 9: ...14 Appendix Spare parts drawing 21 ______________________________________________________________________________________________________ EU Declaration of Conformity Manufacturer ZEHNDER Pumpen GmbH...

Страница 10: ...nufacturer we will be at your disposal after the buying for near information In cause of defects or damages please contact your retail trader Manufacturer ZEHNDER Pumpen GmbH Zw nitzer Stra e 19 08344...

Страница 11: ...contents of the operating instructions are fully understood by the personnel This equipment may be used by children over 8 years of age and over as well as by persons with reduced physical sensory or...

Страница 12: ...nits have a 10m power supply cable with plug for 230V 50Hz single phase Other voltages are possible on demand Please note the data printed on the type plate This pump must be connected to an earthed o...

Страница 13: ...rson 6 Warranty This pump carries a 24 month manufacturer warranty The warranty period begins with the date of purchase by the end user Proof of purchase should be retained Within this period we will...

Страница 14: ...sket 150 032 150 032 150 032 290 2 Screwed cable gland PG 11 Ms 200 124 200 124 200 124 300 4 Ejot Scew PT KA 40x10 WN 1412 800 030 800 030 800 030 301 4 Seal 8 5x3 3x1 0 100 911 100 911 100 911 305 1...

Страница 15: ...ts cause et limination 19 10 Liste de pi ces de rechange 20 Annexe Dessin des pi ces de rechange 21 ____________________________________________________________________________________________________...

Страница 16: ...On peut conclure la date de production du num ro de s rie tat du manuel d utilisation 03 2017 1 2 Demandes et commandes Veuillez adresser vos demandes et commandes votre marchand sp cialis ou votre d...

Страница 17: ...on de personnel et formation Le personnel pour le fonctionnement l entretien l inspection et de montage doit avoir les qualifications requises pour ce travail Les responsabilit s la comp tence et la s...

Страница 18: ...rge des cons quences 2 8 Modes de fonctionnement inadmissibles La s curit de travail de l unit livr e n est garantie que lors d une utilisation conform ment la section 1 G n ralit s du manuel d utilis...

Страница 19: ...oix avec le d pannage ou l change de l unit Dommages en r sultant de l usage inappropri l usure roue et joint d tanch it rotatif ou les contaminations sont exempt s de la garantie En outre le droit de...

Страница 20: ...200 061 230 1 Condensateur 900134 279911 279911 240 1 Bornier 270027 270027 270027 250 1 Poign e 100 303 100 303 100 303 270 2 Vis pour poign e M5x8 A2 800 087 800 087 800 087 280 2 Joint d tanch it e...

Страница 21: ...21 Anhang Appendix Annexe Ersatzteilzeichnung Spare parts drawing Dessin des pi ces de rechange E ZW 50 A 2...

Страница 22: ...22 Ersatzteilzeichnung Spare parts drawing Dessin des pi ces de rechange E ZW 65 A...

Страница 23: ...23 Ersatzteilzeichnung Spare parts drawing Dessin des pi ces de rechange E ZW 80 A...

Страница 24: ...24 ______________________________________________________________________________________________________ 2017 ZEHNDER Pumpen GmbH...

Отзывы: