background image

EN - 8

CE certification 

Zehnder Group Nederland B.V.
Lingenstraat 2 • 8028 PM Zwolle-NL
T +31 (0)38 4296911 • F +31 (0)38 4225694
Company register Zwolle 05022293

 

 

 

 

 

 

EEC declaration of conformity

Machine description  

 

 

Heat recovery units: 

ComfoAir 160, 200, 350, 550 series

Complies with the following directives 

Machinery Directive 

(2006/42/EEC)

 

 

 

 

 

 

Low Voltage Directive   (2006/95/EEC)

 

 

 

 

 

 

EMC Directive    

(2004/108/EEC)

Zwolle, 15-01-2014
Zehnder Group Nederland B.V.

O. Schulte,
Director Production Zwolle

3  CE certification and warranty

Warranty conditions

The unit is covered by a manufacturer’s warranty for 
a period of 24 months after fitting up to a maximum 
of 30 months after the date of manufacture. Warranty 
claims may only be submitted for material faults and/
or construction faults arising during the warranty 
period. In the case of a warranty claim, the unit 
must not be dismantled without written permission 
from the manufacturer. Spare parts are only covered 
by the warranty, if they were supplied by the 
manufacturer and have been installed by an  
approved installer.

The warranty becomes invalid if:

The guarantee period has elapsed;
The device is used without filters;
 Parts are used that have not been supplied by the 
manufacturer;
 Non-authorised changes or modifications have 
been made to the unit.
 Installation has not been carried out  
according to the applicable regulations;
 The defects are due to incorrect connection, 
inexpert use, or contamination of the system; 

 On-site (dis)assembly costs are not covered by the 
terms of the warranty. This also applies to normal 
wear and tear. Zehnder retains the right to change 
the construction and/or configuration of its products 
at any time without being obliged to alter previously 
delivered products.

Liability

 The unit has been designed and manufactured for 
use in balanced ventilation systems incorporating 
Zehnder heat recovery systems. Any other 
application is seen as inappropriate use and can 
result in damage to the unit or  personal injury, for 
which the manufacturer cannot be held liable. The 
manufacturer is not liable for any damage originating 
from:

 Non-compliance with the safety, operating and 
maintenance instructions in this document;
 The use of components not supplied or  
recommended by the manufacturer. 
 Responsibility for the use of such  
components lies entirely with the installer;
 Normal wear and tear.

 End of useful life

 Consult with the supplier about what should be 
done with the unit at the end of its useful life. If 
the unit cannot be returned to the supplier, avoid 
disposing of it with the domestic waste, and ask 
your local council about the options for recycling 
the components or processing the materials in an 
environmentally friendly manner.
 Furthermore, do not dispose of batteries from the 
wireless (RF) switches with the normal waste, but 
bring them to the specially designated disposal 
locations.

Содержание ComfoAir 350

Страница 1: ...1 EN Ventilation system ComfoAir Luxe User document Cooling Fresh Air Clean Air Heating ComfoAir 160 ComfoAir 200 ComfoAir 450 ComfoAir 550 ComfoAir 350 ...

Страница 2: ...performance of the device is compromised if instructions are not observed carefully Risk of personal injury for the user Maintenance Questions Please contact the supplier if you have any questions or would like to order a new document or new filters The contact details of the main supplier can be found on the rear flap of this document The following information can be found in this document Inform...

Страница 3: ...4 Maintenance 9 4 1 Cleaning or replacing the filters 9 4 1 1Replacing the internal filters 10 4 1 2 Cleaning the internal filters 11 4 1 3 Replacing or cleaning the external filter 11 4 2 Cleaning the valve 11 4 3 Condensation drain 11 4 4 Maintenance by the installer or maintenance mechanic 11 5 Malfunctions 11 I Commissioning Inspection Record 12 II Maintenance log 13 ...

Страница 4: ...EN 4 ...

Страница 5: ...chen bathroom the toilet and if present the storage room E Safety instructions Always follow the safety regulations warnings comments and instructions given in this document Personal injury or damage to the unit can arise from non compliance with the safety regulations warnings comments and instructions in this document It is recommended to take out a maintenance contract so that the device is che...

Страница 6: ...the ComfoHood on and off Indicating and setting the comfort temperature Setting the P menus Resetting the malfunctions and filter alert Setting a preset ventilation programme Setting and showing date and time CC Luxe Indicating and setting the desired ventilation level A Absent 1 Low 2 Normal 3 High Overrun timer Preset programme Indicating a malfunction or filter alert Indicating if the bypass pr...

Страница 7: ...k to the normal setting 0 Min 120 Min 30 Min P23 n a 0 Min 120 Min 0 Min P24 Filter warning x weeks after cleaning the filters the filter dirty alert will reappear 10 weeks 26 weeks 16 weeks P25 Only applies to systems fitted with an RFZ swith Overrun timer for ventilation setting 3 using After pressing briefly 2 sec the unit will switch to the high setting for x minutes and then automatically ret...

Страница 8: ...ing to the applicable regulations The defects are due to incorrect connection inexpert use or contamination of the system On site dis assembly costs are not covered by the terms of the warranty This also applies to normal wear and tear Zehnder retains the right to change the construction and or configuration of its products at any time without being obliged to alter previously delivered products L...

Страница 9: ...g reasons If the power to the unit is disconnected mechanical ventilation of the dwelling will cease This can lead to a build up of moisture and results in problems with mould 4 1 Cleaning or replacing the filters Replace the filters at least every six months and clean the filters every 2 or 3 months When indicated on the ComfoSense or CC Luxe you must clean or replace the filters The installer of...

Страница 10: ...unit A A ComfoAir 350 A A ComfoAir 550 4 B ComfoAir 160 200 ComfoAir 350 550 Remove the dirty filters B from the unit 5 Install the clean filter back into the unit and reconnect the power When using the unit for the first time it is recommended to replace the filters and clean the valves first During the construction phase the ventilation system could have become dirty with building dust Only avai...

Страница 11: ...he ventilation system Therefore do not change the setting of the valves 4 3 Condensation drain Ensure that the water seal u bend connected to the domestic waste water system is always full of water 4 4 Maintenance by the installer or maintenance mechanic Not all neccesary maintenance can be done by the user Once every 2 years the installer or a maintenance mechanic should come by for the maintenan...

Страница 12: ...Return Room Position Required m3 h Tested m3 h Type valve Settings valve Settings unit Kitchen P30 Bathroom P31 Toilet P32 P33 Total Supply Room Position Required m3 h Tested m3 h Type valve Settings valve Settings unit Living room P34 Bedroom 1 P35 Bedroom 2 P36 Bedroom 3 P37 Total Pressure Measured Supply Pa Return Pa Press pressure Suction pressure Total ...

Страница 13: ...ths after installation Activity Y1 Y2 Y3 Y4 Y5 Y6 Y7 Clean the filters 12 months after installation Activity Y1 Y2 Y3 Y4 Y5 Y6 Y7 Replace the filters Clean the valves Inspect and clean the condensation drain Inspect and clean the air ducts Inspect and clean the casing of the unit Inspect and clean the heat exchanger Inspect and clean the fans Inspect and clean the pre heater filter Date Activity I...

Страница 14: ... installation Activity Y8 Y9 Y10 Y11 Y12 Y13 Y14 Clean the filters 12 months after installation Activity Y8 Y9 Y10 Y11 Y12 Y13 Y14 Replace the filters Clean the valves Inspect and clean the condensation drain Inspect and clean the air ducts Inspect and clean the casing of the unit Inspect and clean the heat exchanger Inspect and clean the fans Inspect and clean the pre heater filter Date Activity ...

Страница 15: ...15 EN ...

Страница 16: ...Zehnder Group Nederland B V Lingenstraat 2 8028 PM Postbus 621 8000 AP Zwolle T 31 38 429 69 11 F 31 38 422 56 94 ventilatie zehnder nl www zehnder nl ZGNL Manual_40002051 V0117 EN Subject to change ...

Отзывы: