7 - EN
2.2 P menus for the user
A summary of all the accessible P-menus is given
below.
Menu P1 > Status of time programmes
Status
Submenu
Description
Activated
P10**
Is menu P20 currently
active?
Yes (1) / No (0)
P11
Is menu P21 currently active? Yes (1) / No (0)
P12
Is menu P22 currently
active?
Yes (1) / No (0)
P13
Is menu P23 currently
active?
Yes (1) / No (0)
P14
Is menu P24 currently active? Yes (1) / No (0)
P15
Is menu P25 currently active? Yes (1) / No (0)
P16
Is menu P26 currently
active?
Yes (1) / No (0)
P19**
Is menu P29 currently
active?
Yes (1) / No (0)
Menu P9 > Status of additional programmes
Status
Submenu
Description
Activated
P90
Open fire programme active?
Yes (1) / No (0)
P91
Bypass open?
Yes (1) / No (0)
P92**
ComfoFond-L** valve open?
Yes (1) / No (0)
P93**
Post heater on?
Yes (1) / No (0)
P94
Analogue input (0-10V)
active?
Yes (1) / No (0)
P95
Frost protection or pre
heater active?
Yes (1) / No (0)
P96**
ComfoHood** on?
Yes (1) / No (0)
P99
Enthalpy programme active?
Yes (1) / No (0)
Menu P2 > Setting time delays
Time delay values
Submenu
Description
Minimum
Maximum
General
reset
P20**
Only applies to systems
fitted with a ComfoHood**.
Overrun timer for the ComfoHood** programme.
■
’x’ minutes after operating the ComfoHood** switch the
unit reverts back to the normal setting.
0 Min.
180 Min.
0 Min.
P21
Delay timer for the bathroom switch (to switch to high
position).
■
‘x‘ minutes after operating the bathroom switch,
the unit switches to the high setting.
0 Min.
15 Min.
0 Min.
P22
Overrun timer for the bathroom switch (to switch to normal
position).
■
‘x‘ minutes after operating the bathroom switch, the unit
switches back to the normal setting.
0 Min.
120 Min.
30 Min.
P23
n/a
0 Min.
120 Min.
0 Min.
P24
Filter warning
■
‘x’ weeks after cleaning the filters the “filter dirty” alert
will reappear.
10 weeks
26 weeks
16 weeks
P25
Only applies to systems
fitted with an RFZ swith.
Overrun timer for ventilation setting 3 (using
).
■
After pressing
briefly (< 2 sec.), the unit will switch to
the high setting for ‘x’ minutes and then
automatically returns to the normal setting.
If any switch is operated during this lagging time the unit will
instantly revert to the ventilation position as set at that time.
1 Min.
20 Min.
10 Min.
P26
Only applies to systems
fitted with an RFZ swith.
Overrun timer for ventilation setting 3 (using
).
■
After pressing
continously (> 2 sec.), the
unit will switch to the high setting for ‘x’ minutes and then
automatically returns to the normal setting.
If any switch is operated during this lagging time the unit will
instantly revert to the ventilation position as set at that time.
1 Min.
120 Min.
30 Min.
P27
Only applies to systems
fitted with a ComfoSense
or CC Luxe**.
Time for the boost setting.
■
After pressing
on the CC Luxe** or after
turning on the PARTY TIMER on the ComfoSense, the
unit will switch to the high setting for ‘x’ minutes and then
automatically returns to the normal setting.
If any switch is operated during this lagging time the unit will
instantly revert to the ventilation position as set at that time.
0 Min.
120 Min.
30 Min.
P29**
Only applies to systems
fitted with a ComfoHood**.
Setting the ComfoHood** ventilation levels.
■
When the ComfoHood** is switched on the ComfoHood**
ventilation settings can be set x-% higher than the
corresponding ‘normal’ ventilation levels.
1%
99%
10%
** Only available on the ComfoAir350Luxe and ComfoAir550Luxe.
Содержание ComfoAir 350
Страница 4: ...EN 4 ...
Страница 15: ...15 EN ...