background image

   11 - EN

4.1.2  Cleaning the internal filters 

Vacuum the filters (B) with a vacuum cleaner instead 
of replacing them with new filters.

  

 When using the unit for the first time, it 
is recommended to clean the filters (and 
valves) first. During the construction phase 
the ventilation system could have become 
dirty with building dust.

4.1.3  Replacing or cleaning the external 

filter 

If so indicated on the ComfoSense or CC Luxe** you 
must clean or replace the filter as is mentioned in the 
external filter document.

4.2  Cleaning the valve 

Clean the valves (at least) twice a year.

1.  Mark the setting of the valve; 
2. Remove the valve from the wall or ceiling;
3.  Clean the valve in a solution of soap and warm 

water;

4. Rinse the valve thoroughly and wipe dry;
5.  Place the valve back WITH EXACTLY THE SAME 

SETTING (and IN THE SAME HOLE);

6. Repeat this procedure for the other valves.

  

 Some valves have a filter behind it. If a filter 
is present clean this in the same way as the 
valve.

About the valve settings

 The ventilation air is supplied and discharged 
by means of valves. Gaps under or near doors 
in the dwelling ensure that the air flows in the 
right direction. In order to ensure that the correct 
ventilation volumes are maintained in the rooms, the 
following must be observed:

 Do not seal the gaps under or near the doors. For 
example by furniture, draught excluders or deep-
pile carpet. The gap should be at least 2cm;
Do not change the settings of the valves;
Do not replace the valves with one another.

 The installer will have set all the valves to ensure 
the optimum performance of the ventilation system. 
Therefore, do not change the setting of the valves.

4.3 Condensation drain 

Ensure that the water seal (u-bend) connected to the 
domestic waste-water system is always full of water.

4.4 Maintenance by the installer or 

maintenance mechanic 

 Not all neccesary maintenance can be done by  
the user. 

 

  Once every 2 years the installer or a maintenance 

mechanic should come by for the maintenance 
inside the balanced ventilation system. 

Some installers offer a full maintenance contract 
package where the user maintenance can also be 
integrated.

5  Malfunctions

In the event of a malfunction, the corresponding 
malfunction code will be displayed on the 
ComfoSense or CC Luxe** of the unit.

In event of a filter malfunction the filter must be 
cleaned or replaced as described in the Maintenance 
chapter.
In the event of all other malfunction:

Action

Explanation

1

Note down the malfunction code that 
appears on the ComfoSense or CC Luxe** 
of the unit.

2

Note down the unit type.
This is given on the identification plate on 
the unit near the power supply.

3

Contact the installer or maintenance 
mechanic
and give him the  noted information.

The system should not be disconnected from the 
power supply, unless the unit must be taken out of 
service due to a serious malfunction, or for filter 
cleaning/replacement or any other compelling 
reasons. 

  

 If the unit is disconnected from the power 
supply, mechanical ventilation of the 
dwelling will cease. This can lead to a build-
up of moisture and results in problems with 
mould. 

 

 

 I

f the unit is installed in an area with a higher 

average humidity (such as bathroom or 
toilet) the probability of condensation on the 
outside of the unit is high. This is similar to 
condensation on a window and no action is 
needed.

** Only available on the ComfoAir350Luxe and ComfoAir550Luxe.

Содержание ComfoAir 350

Страница 1: ...1 EN Ventilation system ComfoAir Luxe User document Cooling Fresh Air Clean Air Heating ComfoAir 160 ComfoAir 200 ComfoAir 450 ComfoAir 550 ComfoAir 350 ...

Страница 2: ...performance of the device is compromised if instructions are not observed carefully Risk of personal injury for the user Maintenance Questions Please contact the supplier if you have any questions or would like to order a new document or new filters The contact details of the main supplier can be found on the rear flap of this document The following information can be found in this document Inform...

Страница 3: ...4 Maintenance 9 4 1 Cleaning or replacing the filters 9 4 1 1Replacing the internal filters 10 4 1 2 Cleaning the internal filters 11 4 1 3 Replacing or cleaning the external filter 11 4 2 Cleaning the valve 11 4 3 Condensation drain 11 4 4 Maintenance by the installer or maintenance mechanic 11 5 Malfunctions 11 I Commissioning Inspection Record 12 II Maintenance log 13 ...

Страница 4: ...EN 4 ...

Страница 5: ...chen bathroom the toilet and if present the storage room E Safety instructions Always follow the safety regulations warnings comments and instructions given in this document Personal injury or damage to the unit can arise from non compliance with the safety regulations warnings comments and instructions in this document It is recommended to take out a maintenance contract so that the device is che...

Страница 6: ...the ComfoHood on and off Indicating and setting the comfort temperature Setting the P menus Resetting the malfunctions and filter alert Setting a preset ventilation programme Setting and showing date and time CC Luxe Indicating and setting the desired ventilation level A Absent 1 Low 2 Normal 3 High Overrun timer Preset programme Indicating a malfunction or filter alert Indicating if the bypass pr...

Страница 7: ...k to the normal setting 0 Min 120 Min 30 Min P23 n a 0 Min 120 Min 0 Min P24 Filter warning x weeks after cleaning the filters the filter dirty alert will reappear 10 weeks 26 weeks 16 weeks P25 Only applies to systems fitted with an RFZ swith Overrun timer for ventilation setting 3 using After pressing briefly 2 sec the unit will switch to the high setting for x minutes and then automatically ret...

Страница 8: ...ing to the applicable regulations The defects are due to incorrect connection inexpert use or contamination of the system On site dis assembly costs are not covered by the terms of the warranty This also applies to normal wear and tear Zehnder retains the right to change the construction and or configuration of its products at any time without being obliged to alter previously delivered products L...

Страница 9: ...g reasons If the power to the unit is disconnected mechanical ventilation of the dwelling will cease This can lead to a build up of moisture and results in problems with mould 4 1 Cleaning or replacing the filters Replace the filters at least every six months and clean the filters every 2 or 3 months When indicated on the ComfoSense or CC Luxe you must clean or replace the filters The installer of...

Страница 10: ...unit A A ComfoAir 350 A A ComfoAir 550 4 B ComfoAir 160 200 ComfoAir 350 550 Remove the dirty filters B from the unit 5 Install the clean filter back into the unit and reconnect the power When using the unit for the first time it is recommended to replace the filters and clean the valves first During the construction phase the ventilation system could have become dirty with building dust Only avai...

Страница 11: ...he ventilation system Therefore do not change the setting of the valves 4 3 Condensation drain Ensure that the water seal u bend connected to the domestic waste water system is always full of water 4 4 Maintenance by the installer or maintenance mechanic Not all neccesary maintenance can be done by the user Once every 2 years the installer or a maintenance mechanic should come by for the maintenan...

Страница 12: ...Return Room Position Required m3 h Tested m3 h Type valve Settings valve Settings unit Kitchen P30 Bathroom P31 Toilet P32 P33 Total Supply Room Position Required m3 h Tested m3 h Type valve Settings valve Settings unit Living room P34 Bedroom 1 P35 Bedroom 2 P36 Bedroom 3 P37 Total Pressure Measured Supply Pa Return Pa Press pressure Suction pressure Total ...

Страница 13: ...ths after installation Activity Y1 Y2 Y3 Y4 Y5 Y6 Y7 Clean the filters 12 months after installation Activity Y1 Y2 Y3 Y4 Y5 Y6 Y7 Replace the filters Clean the valves Inspect and clean the condensation drain Inspect and clean the air ducts Inspect and clean the casing of the unit Inspect and clean the heat exchanger Inspect and clean the fans Inspect and clean the pre heater filter Date Activity I...

Страница 14: ... installation Activity Y8 Y9 Y10 Y11 Y12 Y13 Y14 Clean the filters 12 months after installation Activity Y8 Y9 Y10 Y11 Y12 Y13 Y14 Replace the filters Clean the valves Inspect and clean the condensation drain Inspect and clean the air ducts Inspect and clean the casing of the unit Inspect and clean the heat exchanger Inspect and clean the fans Inspect and clean the pre heater filter Date Activity ...

Страница 15: ...15 EN ...

Страница 16: ...Zehnder Group Nederland B V Lingenstraat 2 8028 PM Postbus 621 8000 AP Zwolle T 31 38 429 69 11 F 31 38 422 56 94 ventilatie zehnder nl www zehnder nl ZGNL Manual_40002051 V0117 EN Subject to change ...

Отзывы: