3 - EN
2 For the Installer
2.1 ComfoAir configuration
The standard ComfoAir configuration consists of:
• External casing (A) of coated sheeting;
• Interior (B) of EPP;
• 4 connections of EPP (C) for the air ducts;
• 2 filters (D) for air purification; Type G4 for outside air and type G4 for return air;
• 2 energy-efficient DC motors (E) with high-efficient fan and constant volume;
• HE (High Efficient) heat exchanger (F);
• Connector panel (L) with connections for the CC-Ease, the enthalpy exchanger and the two 0 -10 V controls;
• Electronic box with PCB panel (H) with connections for the fans, the bypass temperature sensors (T1 to T4), the
3-position switch with or without malfunction and filter indication (optional) and the bathroom switch (optional);
• Identification plate (I) detailing information on the ComfoAir (not visible);
• Condensation drain (J) to drain the condensation of the warm return air;
• Sticker (K) detailing the air connections (not visible);
• Display (G) to read data, and for programming procedures;
• 2 Filtercaps (M);
• 2 Mounting brackets (not visible).