EN - 6
2.3 dimension sketch
2.4 Installation conditions
In order to determine whether the ComfoAir can be
installed in a certain area, the following aspects must
be taken into account:
• The ComfoAir must be installed according to the
general and locally applicable safety and installa-
tion regulations of power and water companies, as
well as the instructions in this manual.
• The system must be fitted to allow sufficient room
around the ComfoAir for the air connections and
supply and exhaust ducts as well as for carrying
out maintenance activities.
• The ComfoAir must be installed in a frost-free space.
The condensation must be drained off frost-free, at a
gradient and incorporate a 'U' bend.
Condensation may form on the outside of
the ComfoAir if the unit is fitted in a space
with higher average humidity levels (such as
a bathroom, shower, toilet or kitchen). This is
not a problem for the ComfoAir.
• The room must offer the following provisions:
-
Air duct connections.
- 230V electrical connection.
- Provisions for the condensation drain.
- Wiring for an wired 3-position switch
(optional).
• The cable used to connect the CC Ease panel
must have the following specifications:
- Cable type: shielded twisted pair 4x0.34mm
2
.
- Cable length: 10m maximum.
The connections of the CC Ease panel must
be crossed. (Rx must be connected to Tx).
• A gap should be left near the doors in order to
ensure effective and draughtfree airflow in the
house. A gap under the inside doors must be at
least 10mm.
If these openings are obstructed, due to
draught excluders or deep-pile carpet, the
airflow in the house will stagnate. As a result,
system performance will be compromised or
fail altogether.
2.5 Installation of the ComfoAir
2.5.1 Transport and unpacking
Take the necessary precautions when transporting
and unpacking the ComfoAir.
Make sure the packing material is disposed
of in an environmentally friendly manner.
2.5.2 Checking the delivery
Contact your supplier immediately in case of damage
or an incomplete delivery. The delivery must include:
• ComfoAir with 2 mounting brackets installed.
Check the identification plate to ensure that it is
the required type;
• Documentation.
Содержание ComfoAir 160
Страница 1: ...ComfoAir 160 Installer manual...
Страница 4: ......
Страница 32: ...EN 28 2 12 Wiring diagram ComfoAir 160...
Страница 34: ...EN 30...
Страница 35: ...31 EN...