GEMINI

®

 

Twin Port Sampler

Operation Manual

The warranties made by Zefon International Inc. with respect to the 
product are voided if the product is not used and serviced in accordance with the 
instructions in this manual. Please protect yourself and others by following them. 
We encourage our customers to write or call regarding this equipment prior to use 
or for any additional information relative to use or repairs.

In the U.S., contact Zefon at 1-800-282-0073.  
To contact Zefon outside the U.S., dial +1 (352) 854-8080 
or email at [email protected].

© Zefon International, Inc. 2011 - All Rights Reserved

PRODUCT OF U.S.

Manufactured by

ZeFOn InTeRnATIOnAl, InC.

5350 SW 1ST lAne • OCAlA, Fl 34474

(l) Rev 6   

               

800302

WARNING

THIS MANUAL MUST BE CAREFULLY READ BY ALL INDIVIDUALS WHO HAVE OR 
WILL HAVE THE RESPONSIBILITY FOR USING OR SERVICING THE PRODUCT. Like 
any piece of complex equipment, the  instrument will perform as designed only if it 
is used and serviced in accordance with the manufacturer’s instructions. 
OTHERWISE,  IT COULD FAIL TO PERFORM AS DESIGNED AND PERSONS WHO RELY 
ON THIS PRODUCT FOR THEIR SAFETY COULD SUSTAIN SEVERE PERSONAL INJURY  
OR DEATH.

Содержание GEMINI

Страница 1: ...fon outside the U S dial 1 352 854 8080 or email at ZefonCS zefon com Zefon International Inc 2011 All Rights Reserved PRODUCT OF U S Manufactured by Zefon International Inc 5350 SW 1st Lane Ocala FL...

Страница 2: ......

Страница 3: ...Figure 1 3 GEMINI Twin Port Sampler Kit 1 4 Figure 1 4 Inserting Sorbent Tubes into the GEMINI Sampler 1 5 Figure 1 5 Setting the Flow Rate with the DigiCal Calibrator 1 6 Helpful Hints 1 7 Remote Sam...

Страница 4: ......

Страница 5: ...Hiits portions of this manual before using the Sampler Description The GEMINI Sampler is designed to measure concentrations of gases and vapors when used with Zefon or other manufacturer s Sorbent Tub...

Страница 6: ...Chapter 1 Basic Operation Operation Manual 1 2 GEMINI Twin Port Sampler Four Clips one for each Tube Protector and two extra for clipping to the bottom of the GEMINI Sampler and for tubing management...

Страница 7: ...Chapter 1 Basic Operation Operation Manual GEMINI Twin Port Sampler 1 3 Y Connector for multi Sampler applications...

Страница 8: ...rb fitting using the tubing and the adapter supplied The adapter may not be needed for some pumps 2 Turn on the pump and adjust the flow to approximately 1 5 LPM 1 2 to 1 7 LPM As a general rule the p...

Страница 9: ...sampling 5 Install Tubes in the Tube Holders See FIGURE 1 4 6 Preset the flow rates through each Tube to the approximate flow desired see Helpful Hints 3 later in this chapter 7 Connect a length of tu...

Страница 10: ...IGURE 1 5 9 Adjust the needle valve to obtain the desired flow rate through the Tube 10 Repeat steps 6 7 and 8 for the other Tube NOTE The total flow must not exceed 500 ml per minute ml min 11 Instal...

Страница 11: ...50 ml min one turn counterclockwise 200 ml min two turns counterclockwise 350 ml min three turns counterclockwise If samples are to be taken at two different flow rates calibrate and fine adjust the...

Страница 12: ...5 While rotameters or other devices may be used for rough setting of flows their inherent pressure drop adds to the tube load Therefore use only a soap film device the DigiCal 5 Primary Calibrator Pa...

Страница 13: ...inserted so the flow through is in the same direction The stainless steel washer must be placed on the holder before reinstalling the pressure plate To remove the tube holder or to change the filter i...

Страница 14: ...ody 2 Clean the needle by wiping it with a soft tissue 3 If the valve seems to be clogged i e you are unable to achieve 500 ml min flow at 3 1 2 to 4 turns open remove the pressure plate and Tube Hold...

Страница 15: ...er 2 3 NOTE The vacuum setting should read between 18 and 26 w c the flow should read less than 2 ml min 5 Open the needle valve to adjust the flow to achieve 250 to 300 ml min NOTE The vacuum setting...

Страница 16: ...DISC FILTER PUMP 463799 2 2 PLATE PRESSURE SAMPLE TUBE 497711 1 3 CLIP ASSEMBLY 800296 1 4 SCREW 2 56 X 5 16 LG 636267 4 5 WASHER ST STEEL 634257 2 6 HOLDER TUBE 463801 2 7 LABEL FILTER COVER 800095...

Страница 17: ...ECTOR LARGE TUBE 497712 3 CLIP ASSEMBLY 800296 4 SILICONE TUBING 1 8 ID 602294 5 Y FITTING 636563 6 TUBING CONNECTOR 636477 7 TUBING 1 4 ID 27234 8 Label Tamper Proof Sheet of 10 802698 Not Pictured L...

Страница 18: ......

Страница 19: ......

Страница 20: ...To contact Zefon International call 1 800 282 0073 Zefon International Inc 2011 All Rights Reserved PRODUCT OF U S Zefon International Inc 5350 SW 1st Lane Ocala FL 34474...