background image

 

Wireless Data Collector 

 

U

SER

M

ANUAL

Introduction 

The Wireless Data Collector redefines simplicity with more simple features and less 
complicated options. With wireless connectivity, users can transfer data instantly 
allowing seamless, real-time reporting and inventory control. Enhanced with the brand 
new, easy to use ZEBEX Application Creator program, the device allows users to achieve 
maximum efficiency through intuitive settings and user friendly interfaces 

Features 

 

  Transflective LCD for a wide working condition 

 

  No programming background required 

 

 Wireless connectivity 

PC System Requirement 

 

Windows XP Service Pack 2 or above 

 

Microsoft Internet Explorer 5.01 or later 

 

Microsoft Framework 2.0 

Package Contents 

Items contain in the package may vary depending on the model of the data collector. 

 

 

 

Data Collector 

Cradle 

Li-ion Battery 

 

 

 

USB Cable 

Power Adapter 

Hand Strap 

Содержание Z-900 BT Series

Страница 1: ...su Portable Data Collector Series Z 900XRF Version 1 0 User s Manual ZEBEX INDUSTRIES INC WWW ZEBEX COM Wireless Data Collector...

Страница 2: ...History Changes to the original manual are listed below Version Date Description of Version 1 0 11 01 2014 Initial release 1 1 12 25 2015 Updated to new version software 1 2 12 21 2015 Added descripti...

Страница 3: ...is subject to change without notice All trademarks mentioned herein registered or otherwise are the properties of their various respective owners Battery Information Use only a ZEBEX approved batterie...

Страница 4: ...t source Do not place battery into a microwave oven or dryer Battery usage by children should be supervised Please follow local regulations to promptly dispose of used re chargeable batteries Do not d...

Страница 5: ...Wireless Data Collector iii Copyright 2017 All rights reserved Guidance for Printing This manual is in A5 size Please double check your printer setting before printing it...

Страница 6: ...3 DATA CAPTURE 4 GETTING STARTED 7 INSERTING BATTERY 7 CHARGING THE BATTERY 7 INSTALLATION 8 POWER ON THE DEVICE 8 CONNECTING TO PC 9 Connecting via Cradle 9 Running the Device on PC 9 Loading Applic...

Страница 7: ...ower 17 Calculator 17 Load Lookup 18 PROGRAM MANAGER 18 Menu Description 18 Download 19 Activate 20 Upload 21 WIRELESS OPERATION 22 DOWNLOAD FILES 22 Download ZAC Files 22 Download Lookup Files 23 UPL...

Страница 8: ......

Страница 9: ...Creator program the device allows users to achieve maximum efficiency through intuitive settings and user friendly interfaces Features Transflective LCD for a wide working condition No programming ba...

Страница 10: ...nd Strap Hole Used to attach hand straps LED Indicator Indicates reading status Red for scanning error such as wrong data type or no data match and green for good read LCD Screen Display various data...

Страница 11: ...charger off timer 6 2 hrs Memory 8MB FLASH ROM 4MB SRAM with ability to data retentions Keypad 21 keys alpha numeric include Power and SCAN key with white back light LCD Screen LCD type 128 x 128 gra...

Страница 12: ...ology Default Codabar Enable Code 39 Enable Code 93 Enable Code 128 Enable Code 11 Disable Italian Pharmacode Disable Chinese Post Code Disable Interleaved 2 of 5 Enable EAN UPC Enable MSI Disable Tel...

Страница 13: ...Default Codabar N Code 39 M Code 93 L Code 128 K Code 11 O Chinese Post Code H Interleaved 2 of 5 I EAN 13 F UPC A A UPC E E EAN 8 FF MSI P Industrial 2 of 5 D Standard 2 of 5 S Matrix 2 of 5 G GS1 D...

Страница 14: ...ix 2 of 5 Maximum 32 Minimim 6 Maximum 62 Minimim 3 Maximum 62 Minimim 3 Code 39 Code 93 Code 128 Maximum 62 Minimim 3 Chinese Post Code Maximum 16 Minimim 10 Maximum 32 Minimim 4 Interleaved 2 of 5 M...

Страница 15: ...top side in first then the side with battery contact The battery is held in place by a small lock on the bottom of the compartment Push the battery in until it clicks into place 4 Slide the battery c...

Страница 16: ...opens up Double click the found new hardware icon to pull up the window if it does not appear automatically Select No not this time to continue 3 Click Next to continue installation 4 Click Install f...

Страница 17: ...ad and install the driver from ZEBEX website The system should assign a COM port to the device after the driver installation Connect the power adapter to the cradle when necessary Make sure the unit i...

Страница 18: ...up on the data collector 3 Select Send Lookup in ZAC Resetting the Device 1 Press and hold the and buttons then press the Power button 2 Release the Power button when you see the reset message on the...

Страница 19: ...r the menu option Press ESC to go to the previous screen Menu Screen Menu Description Menu Description Collect Select this option to start recording data You can scan barcodes or enter the data manual...

Страница 20: ...Utility Select this option for 1 Settings 2 Browse Data 3 Delete Data 4 Reader Test 5 Set Date Time 6 Load Application 7 Memory Power 8 Calculator 9 Load Lookup when lookup is available this option be...

Страница 21: ...l be activated and shoot out from the window at the lower front end of the data collector Please see the Run Task section in the User s Manual for more details 2 Aim the beam at the barcode to be scan...

Страница 22: ...ble displays the numerical keys and their corresponding alphabetical characters Press the key and the numerical character corresponding to the key will be displayed Pressing the key to switch between...

Страница 23: ...e communication setting for downloading Baud Rate 9600 19200 38400 57600 115200 View the baud rate for connection Backlight Turn B L off Turn B L on Turn the backlight on or off Data Deletion Manual A...

Страница 24: ...to delete data Delete Data Use this option to delete inputted data 1 Select 3 Utilities and 3 Delete Data from the menu 2 Select Date File or a Lookup to delete data 3 Select All data to delete all i...

Страница 25: ...the previous instructions to connect the data collector 2 Select 3 Utilities and 6 Load Application on the data collector 3 Select Send Application in ZAC Memory Power Use this option to display the...

Страница 26: ...Load Lookup on the data collector 3 Select Send Lookup in ZAC Program Manager Press the numeric key 8 and power button at the same time to enter Program Manager Menu Description Menu Description Down...

Страница 27: ...file After the selection connection can only be made when you place the device on the cradle 3 If you selected 1 5 in step 2 you must also select 2 Activate to begin the download procedure 4 If you s...

Страница 28: ...e option from 1 5 and press Enter for detailed information 2 Press F3 to activate once in the detailed information screen 3 Press ESC to exit Program Manager after activation to begin using ZEBEX OS C...

Страница 29: ...stomer Program to PC When uploading the bin file select 1 5 or A to store the file After the selection connection can only be made when you place the device on the cradle Upload 1 z900XRF_fw_x xxx 2 3...

Страница 30: ...For RF SPP Master mode please select 3 Utilities 1 Settings next page 4 Wireless menu 6 Master Connect and enter the host MAC address II For RF SPP Slave mode no additional action is necessary 2 Selec...

Страница 31: ...ect the correct COM port then select Start Download to begin sending files Download Lookup Files 1 To set the device to RF mode select 3 Utilities 1 Settings 2 Download Port from the device menu and s...

Страница 32: ...is necessary 2 Select 3 Utilities 8 Load Lookup and wait for the device to connect An error message may appear if you fail to enter the correct MAC address in SPP Master mode 3 Connect the device to...

Страница 33: ...F SPP Master mode please select 3 Utilities 1 Settings next page 4 Wireless menu 6 Master Connect and enter the host MAC address II For RF SPP Slave mode no additional action is necessary 2 Connect th...

Страница 34: ...Upload Lookup Files 1 To set the device to RF mode select 3 Utilities 1 Settings 1 Upload Port from the device menu and select SPP Master or SPP Slave modes I For RF SPP Master mode please select 3 U...

Страница 35: ...f you fail to enter the correct MAC address in SPP Master mode 3 Connect the device to your computer s serial port using a RF program You may need to enter a pin code to complete the pairing 4 Select...

Страница 36: ...device to RF mode select 3 Utilities 1 Settings 1 Upload Port from the device menu and select SPP Master or SPP Slave modes I For RF SPP Master mode please select 3 Utilities 1 Settings next page 4 Wi...

Страница 37: ...nnection to establish An error message may appear if you fail to enter the correct MAC address in SPP Master mode 6 When connection is established data will transfer to the PC Output to Record 1 Open...

Страница 38: ...s serial port using a RF program You may need to enter a pin code to complete the pairing 5 Select 1 Collect from the data collector menu When you are done entering data press enter and wait for conn...

Страница 39: ...enter Program Manager 3 Select 1 Download and press Enter to enter the Download screen 4 Select an empty slot to to store the file and press Enter Please remember the slot number you selected for lat...

Страница 40: ...wer adapter place the unit in the cradle when ready Please install the driver if necessary 6 On your computer please open the Boot Load Utility default path Start All Programs ZEBEX ZAC Boot Load Util...

Страница 41: ...e then select the firmware file stored on your computer 10 Select Start Boot Load to transfer the file to the device You will hear a beep sound when the transfer is done The Download screen appears on...

Страница 42: ...turn to the Activate screen when the update is done Upgrade Warning Incorrect operation may cause dysfunction or damage to the unit Please choose the correct firmware file Do not remove power or reboo...

Отзывы: