42/50
User Manual for HYD 3-6 kw ES Hybrid Inverter - Rev. 1.1 del 13/06/2019
Identificazione: MD-AL-GI-00
Rev. 4.0 del 31.01.18 - Applicazione: GID
7.
Technical specifications
Model
HYD 3000-ES
HYD 4000-ES
HYD 5000-ES
HYD 6000-ES
Battery parameters
Battery type
Lead-acid, lithium ion
Battery rated voltage
48V
Battery voltage range
42-58V
Recommended battery capacity
200Ah (100– 500 Ah optional)
Maximum charge current
60A
Charge current range
0 - 60A (programmable)
Charge curve
3 - adaptive stage with maintenance
Maximum discharge current
0 - 60A (programmable)
Battery protection
Over-voltage protection / Over-current protection / Over-temperature
protection
Depth of discharge
Lithium: 0 – 80% DOD adjustable
Lead-acid: 0 – 50% DOD adjustable
Photovoltaic Parameters
Maximum input power
3500W
4400W
5500W
6600W
Maximum DC power for each
MPPT
2000W
(160V-520V)
2600W
(200V-520V)
3000W
(250V-520V)
3500W
(300V-520V)
Maximum DC input voltage
600V
DC start-up voltage
120V
Rated DC voltage
360V
MPPT operating voltage range
90-580V
DC voltage range at full load
160V-520V
200V-520V
250V-520V
300V-520V
MPPT number
2
Maximum DC input current
11A/11A
Maximum DC short-circuit
current