Dynamics  

 

 

 

 

The dynamics is a soft knee compressor that is located after the analog to digital converter which will limit 

the dynamic range to prevent clipping during occurrences of loud audio. Dynamics is comprised of both a 

compressor and an expander, which operate jointly

The compressor in the dynamics can set to mild or 

extreme compression and features a soft knee for more transparent operation. 

 

To enter the Dynamics Menu 

Press the INC or DEC key - “PARMS” (parameters) will be displayed on the right.   

To move to the next parameter, press the MENU key.   

To exit this page, hold the MENU key for 1 second. 

 

Dynamics Parameters

 

 

Link L-R:  

OFF / ON:

 

If using a stereo transmitter this links the left and right signal so if one side of the signal 

needs compressing / expansion the other side will do the same to match.

 

 

SPEED 

(Decay Speed)

 :

  SLOWEST / SLOW / NORMAL / FAST / FASTEST 

Sets how 

gradual the signal level decreases after a signal reaches the threshold setting. This is typically set 

to FAST.

 

 

ATTACK 

(Attack Speed) :  SLOWEST / SLOW / NORMAL / FAST / FASTEST 

Sets the speed in how 

fast the gain is reduced once the signal exceeds the threshold setting. This is typically 

set to FAST.

 

 

CMP RATIO 

(Compressor Ratio)

:

  Valid range: 1.0: to 5.0:1, in 0.1

 

steps

.

 

The amount of gain reduction is determined by the compressor ratio setting. 

A compressor ratio for example of 2.0:1 means for every 1 dB above the compressor threshold the gain will 

be reduced 2dB. A higher ratio setting makes the compressor more aggressive. 

 

CMP THRESH

 (Compressor Threshold):  Valid range:  0 to –96dB, in 1dB steps. 

This sets the level in which gain reduction occurs. 

 

CMP KNEE:

  (Compressor Soft Knee):  Valid range:  0 to 20dB, In 1dB steps. 

Sets the compressor's soft knee. A soft knee reduces “softens” the audible change from uncompressed to 

compressed, this is useful especially for higher ratios where the changeover is more noticeable  

 

EXP RATIO 

(Expansion Ratio)

:

  Valid range: 1:1.00 to 1:4.00, In 0.01 steps 

Sets the expansion ratio. For example a 1:2.0 expansion ratio means for every 1 dB below the expansion 

threshold the gain will be reduced 2dB. 

 

EXP THRESH 

(Expansion Threshold)

:

  Valid range:  0 to –96dB, in 1dB steps. 

Sets the threshold above which gain reduction occurs.  

 

REDUCE

 (Expander Gain Reduction)

:

  Valid range:  0 to –36dB, in 1dB steps. 

This sets the limit on the amount of gain reduction caused by the expander.  

 

GAIN

 (Make-up Gain)

:

  Valid range:  0 to 30dB, In 1dB steps.

 

Gain is used to compensate for the gain reduction caused by the compressor. Because the compressor is 

reducing the gain (or level) of the signal, the ability to add a fixed amount of make-up gain at the output is 

provided so that an optimum level can be reached.

DYNAMICS 

Содержание ZMT3-FLEX

Страница 1: ...1 USER MANUAL Published October 2019 Firmware Version ZMT 284 ZMT3 FLEX Transforming Audio...

Страница 2: ...O FRAME RATE ENABLE 8 TRANSMIT MENU 9 UHF TRANSMITTER POWER LEVEL SET 9 UHF TRANSMIT MODULATION SET 9 TRANSMITTER DISABLE RECORD ONLY MODE 9 RECORD MENU 10 SD CARD FORMAT 10 PLAYBACK CONTROL 10 TIME L...

Страница 3: ...20 HIDE TRANSMITTER NAME MENU 20 TRANSMITTER NAME SET 20 RECORDING FORMAT 21 FIRMWARE 22 UPDATING THE ZMT3 FLEX FIRMWARE 22 UPDATING ERX FIRMWARE WITH A ZMT3 FLEX TRANSMITTER 22 UPDATING QRX FIRMWARE...

Страница 4: ...segments Battery This displays the battery type and the approximate percentage of remaining battery power Audio Meter Displays the modulation of the inputted audio signal SEG Gain G Appears when the t...

Страница 5: ...ges When the lock page is landed on a countdown clock will begin After 5 seconds the transmitter will lock and the display will indicated that it is LOCKED If this screen is exited before the 5 second...

Страница 6: ...the transmitter Accessing and navigating the menu groups From in the home screen press the CARD key three times or hold the MENU key while booting up to access the six menu groups Then pressing the I...

Страница 7: ...t s meter Any level above 10 may cause clipping which will prevent proper reading of time code TC Jam Mode Select This menu controls if the ZMT3 Flex will go into record when it receives a record run...

Страница 8: ...being transmitted from the ZaxNet transmitter that is feeding the ZMT3 Flex If auto frame rate is set to OFF the frame rate will need to be adjusted manually Please note that auto frame rate will only...

Страница 9: ...mat the ZMT3 Flex will need to be rebooted by pressing the card key before the new format takes effect MONO STEREO XR ZHD 96 ZHD 48 Modulation Bandwidth 200 kHz 196 kHz 200 kHz 96 kHz 48 kHz Minimum C...

Страница 10: ...longer recognized by the transmitter or by ZaxConvert a partial format can be done The partial format rewrites the FAT32 file structure and leaves the recorded audio untouched To do a partial format...

Страница 11: ...art recording Low Battery Stop Set Low battery stop will set the amount of time after a low battery warning occurs the on board recorder will close the current file and stop recording This is to preve...

Страница 12: ...ency is the frequency that the ZMT3 Flex will get its wireless time code and remote control commands on This frequency will need to match the frequency of the corresponding ZaxNet transmitter The ZaxN...

Страница 13: ...e ZMT3 Flex is assigned a unit code The unit code is a unique number used to identify each ZMT3 Flex within a particular group This allows individual transmitters within the same group to be independe...

Страница 14: ...ransceiver will only receive ZaxNet and NOT go into transmit mode Therefore no ZaxNet TC and or audio will be transmitted This setting shuts off the ZaxNet transmitter Receive then Transmit mode After...

Страница 15: ...ches for ZaxNet time code The settings are NEVER or any interval between 5 and 999 seconds Record Beep Set This menu will only appear if ZaxNet is set to transmit TX mode When the record beep is set t...

Страница 16: ...ter is turned on and adjusted from this menu The high pass filter range is 40Hz to 220Hz in 10Hz increments 2K Notch Filter The 2K notch filter is useful in removing digital RF interference that can b...

Страница 17: ...steps The amount of gain reduction is determined by the compressor ratio setting A compressor ratio for example of 2 0 1 means for every 1 dB above the compressor threshold the gain will be reduced 2...

Страница 18: ...T3 Flex after boot up LOCKED After boot up has completed the transmitter will automatically go into lock mode and the keys will be locked to prevent accidental changes to the settings UNLOCKED After b...

Страница 19: ...intervals Information Page This page displays the current firmware version the serial number the DSP version and the option code Hide Encryption Menu This setting will hide the encryption menu A hidde...

Страница 20: ...e MENU key for 1 second Hide Transmitter Name Menu This setting will hide the name menu A hidden name menu allows for quicker navigation and prevents accidental changes HIDDEN The name menu doesn t ap...

Страница 21: ...must be formatted in a 3 series transmitter to work properly cards formatted in any other series transmitter will not record properly Please note that regardless of the size of the card the onboard r...

Страница 22: ...30 seconds 8 Upon completion cycle the power and confirm that the transmitter is running the new firmware WARNING Before updating the firmware be sure to insert a fresh battery and do not power down t...

Страница 23: ...n will display waiting for program This indicates the receiver is ready to download the new firmware This can be done to several QRXs so they will be updated at the same time 5 At the transmitter proc...

Страница 24: ...x Operating Frequencies 24 Operating Frequencies ZaxNet Remote Control and Time Code 2 403 to 2 475 GHz UHF Audio ZMT3 5 512 0 MHz to 614 0 MHz Blocks 20 through 23 ZMT3 6 596 0 MHz to 698 0 MHz Block...

Страница 25: ...Zaxcom ZMT3 Flex Antenna Cutting Chart 25...

Страница 26: ...dates Download the latest User Manuals from http zaxcom com support updates Submit Technical Questions at http www zaxcom com submit a technical question Submit information for Repair Services at http...

Страница 27: ...2 Input Range 60 to 30 dBu ADC Bit Depth 24 Bits ADC Sampling Rate 48kHz Time code Reader Generator Clock Accuracy 1 54PPM 1 Frame Out in 6 Hours Time code Type SMPTE Time code Frame Rates 23 98 24 2...

Страница 28: ...ar Product Limitation of Remedies Your exclusive remedy for any defective Product is limited to the repair or replacement of the defective Product Zaxcom may elect which remedy or combination of remed...

Страница 29: ...ente p i r e ne d passe pas l intensit n cessaire l tablissement d une communication satisfaisante Le pr sent metteur radio PR6 XRT a t approuv par Industrie Canada pour fonctionner avec les types d a...

Страница 30: ...30...

Отзывы: