AUX
OUTPUT
STOP
ON
RAMP
F9
OUTPUT
BEHAVIOUR ON A SLOPE
BRAKE
ON
-It drives the coil of a
electromagnetic brake.
-The hydraulic steering function
request is sent to the pump
inverter by the can-bus link.
The truck is electrically hold on a
slope; when the time set by
""auxiliary time"" parameter is
elapsed the brake is applied and
the 3-phase bridge is released.
Do not use this combination if
the negative brake is not
installed.
BRAKE
OFF
-It drives the coil of a
electromagnetic brake.
-The hydraulic steering function
request is sent to the pump
inverter by the can-bus link.
The truck is not electrically hold
on a slope, but comes down
very slowly; when the time set
by ""auxiliary time"" parameter is
elapsed, the brake is applied
and the 3-phase bridge is
opened.
Do not use this
combination if the negative
brake is not installed.
HYDRO
CONT.
ON
-It drives the coil of a hydraulic
steering contactor.
-The hydraulic steering function
request is also sent to the pump
inverter by the can-bus link.
The truck is electrically hold on a
slope; when the time set by
""auxiliary time"" parameter is
elapsed, the truck comes down
very slowly, till the flat is
reached.
HYDRO
CONT.
OFF
-It drives the coil of a hydraulic
steering contactor.
-The hydraulic steering function
request is also sent to the pump
inverter by the can-bus link.
The truck is not electrically hold
on a slope, but comes down
very slowly till the flat is
reached.
EXCL.
HYDRO
ON
-It drives the coil of a hydraulic
steering contactor.
-The hydraulic steering function
request is also sent to the pump
inverter by the can-bus link.
The truck is electrically hold on a
slope; when the time set by
""auxiliary time"" parameter is
elapsed, the truck comes down
very slowly, till the flat is
reached.
EXCL.
HYDRO
OFF
-It drives the coil of a hydraulic
steering contactor.
-The hydraulic steering function
request is also sent to the pump
inverter by the can-bus link.
The truck is not electrically hold
on a slope, but comes down
very slowly till the flat is
reached.
5.4.2 Pump
Using the config menu of the programming console, the user can configure the
following functions.
SUBMENU "SET OPTIONS"
1) HOUR
COUNTER
-
RUNNING: the counter registers travel time only.
-
KEY ON:
the counter registers when the "key" switch is closed.
2) BATTERY
CHECK
-
ON: the battery discharge level check is carried out; when the battery
level reaches 10%, an alarm is signalled and the maximum current is
reduced to the half of the programmed value.
ADEZP0AE - AC-2 INVERTER - User Manual
Page - 31/64
Содержание AC-2
Страница 21: ...4 8 Mechanical drawing ADEZP0AE AC 2 INVERTER User Manual Page 21 64...
Страница 22: ...4 9 Connection drawing Traction configuration Page 22 64 ADEZP0AE AC 2 INVERTER User Manual...
Страница 23: ...4 10Connection drawing Pump configuration ADEZP0AE AC 2 INVERTER User Manual Page 23 64...
Страница 24: ...4 11Connection drawing Combi configuration Page 24 64 ADEZP0AE AC 2 INVERTER User Manual...
Страница 49: ...12 Press OUT to return to the Opening Zapi Display ADEZP0AE AC 2 INVERTER User Manual Page 49 64...