![ZAPbp BP93p Скачать руководство пользователя страница 24](http://html1.mh-extra.com/html/zapbp/bp93p/bp93p_operators-manual_3155724024.webp)
10
Stopping the process:
Travel has been paused by pressing the
[STOP]
key.
Critical ruler error
: The ruler does not report that it has completed travel, although the motor
responsible for movement along a given axis has received a message about completion of travel. This
error occurs, when:
a.
There is a motor malfunction;
b.
There is a motor controller malfunction;
c.
The travelling structure produces too much resistance during movement (if that is the case, it
is recommended to clean and re-lubricate the power screw).
2.1.9
Limiting switches
If the upper of lower limiting switch has been reached, it is signalled by the following message displayed on the
screen:
“
k+
”
or
“
k-
”
, respectively, with the value of axis coordinate corresponding to the value that triggered a
limiting switch.
.
2.2
Configuration of coordinates
2.2.1
Operator’s coordinates
Intended use:
This function enables changing values for each of the operator's coordinates. This way, it is
possible to change the datum point corresponding to a local co-ordinate system, in relation to the datum point
corresponding to a global co-ordinate system.
Access path:
Manual Mode [R] -> Configuration of coordinates -> Operator
’
s coordinates
Screen:
Course of action:
1)
Select a specific character and the axis for which we intend to declare new operator’s coordinates, by
pressing an appropriate key included in the directional keypad (see Fig. 1).
o
The entry window dedicated to the selected axis will be displayed.