22
GB
Activated charcoal filter (Recirculation version)
REPLACING THE ACTIVATED CHARCOAL FILTER
Lighting
LIGHT REPLACEMENT
• The filter is not washable and cannot be
regenerated. It must be replaced when led
S2
flashes or at least every 4 months. The alarm
signal will only light up when the extractor motor
is switched on.
Alarm signal reset
• Switch off the lights and extractor motor.
• Press button
V3
for at least 3 seconds, until the
leds start to flash.
Replacing the Filter
• Remove the metal grease filters
• Remove the saturated activated carbon filter by
releasing the fixing hooks
• Fit the new filter by hooking it into its seating
• Replace the metal grease filters.
Alarm signal activation
• On the recirulcation version extractor hood, the
filter saturation alarm is activated during
installation or at a later date.
• Switch off the lights and extractor motor.
• Press button
V3
for at least 10 seconds, until the
leds start to flash:
• 2 flashes of the activated carbon odour filter
saturation alarm led = filter ACTIVATED
• 1 flash of the activated carbon odour filter
saturation alarm led = filter DEACTIVATED
• 20 W halogen light.
• Remove the 2 screws fixing the ring nut.
• Extract the lamp from the lamp holder by pulling
gently.
• Replace with another of the same type, making
sure that the two pins are properly inserted in the
lamp holder socket holes.
• Replace the ring nut and fix it in place using the
two screws removed as above.
Содержание ZHC 930 X
Страница 4: ...15 GB CHARACTERISTICS Dimensions ø 280 890 min 1170 max 732 898 55 72 500 890 ...
Страница 12: ......