TROUBLESHOOTING
WARNING! Refer to Safety chapters.
WHAT TO DO IF...
Problem
Possible cause
Remedy
There is no spark when you try
to activate the spark generator.
The hob is not connected to an
electrical supply or it is con-
nected incorrectly.
Check if the hob is correctly
connected to the electrical
supply.
The fuse is blown.
Make sure that the fuse is the
cause of the malfunction. If the
fuse is blown again and again,
contact a qualified electrician.
Burner cap and crown are
placed incorrectly.
Place the burner cap and
crown correctly.
The flame extinguishes immedi-
ately after ignition.
Thermocouple is not heated up
sufficiently.
After lightning the flame, keep
the knob pushed for equal or
less than 10 seconds.
The flame ring is uneven.
Burner crown is blocked with
food residues.
Make sure that the injector is
not blocked and the burner
crown is clean.
IF YOU CANNOT FIND A SOLUTION...
If you cannot find a solution to the problem yourself,
contact your dealer or an Authorised Service
Centre. Give the data from the rating plate. Make
sure, you operated the hob correctly. If not the
servicing by a service technician or dealer will not
be free of charge, also during the warranty period.
The instructions about the Service Centre and
conditions of guarantee are in the guarantee
booklet.
24
Содержание ZGG62414WA
Страница 46: ...46 ...
Страница 47: ...47 ...
Страница 48: ...WWW ZANUSSI COM SHOP 867329815 C 262018 ...