Stacking kit (optional accessory)
It should be possible to stack your new dryer on top
of a front loading washing machine with cover’s
depth between 48 and 60 cm.
Read carefully the instructions supplied with the kit.
Please contact your local Service Force Centre for
further advice.
Door reversal
To make it easier to load or unload the laundry the
door can be reversed.
This operation must be carried out by qualified
personnel.
Please contact the nearest Zanussi Service Force
Centre.
Electrical connection
Any electrical work required to install this appliance
should be carried out by a qualified electrician or
competent person.
WARNING: THIS APPLIANCE MUST BE
EARTHED.
The manufacturer declines any liability
should this safety measure not be observed.
Should the appliance power supply cable
need to be replaced, this must be carried out
by our Service Centre.
Before switching on, make sure the electricity supply
voltage is the same as that indicated on the
appliance’s rating plate. (See picture on page 4).
The appliance is supplied with a 13amp plug fitted.
In the event of having to change the fuse in the plug
supplied, a 13amp ASTA approved BS 1363/A fuse
must be used.
P1148
16
Unpacking
Warning !
Slide out the polythene bag containing the
polystyrene block before using the appliance.
Should the appliance be moved, it must be
transported vertically.
Positioning
It is recommended that, for your convenience, the
machine is positioned close to your washing
machine.
The tumble dryer must be installed in a clean place,
where dirt does not build up.
Air must be able to circulate freely all round the
appliance. Do not obstruct the front ventilation grille
or the air intake grilles at the back of the machine.
To keep vibration and noise to a minimum when the
dryer is in use, it should be placed on a firm, level
surface.
Once in its permanent operating position, check that
the dryer is absolutely level with the aid of a spirit
level. If it is not, raise or lower the feet until it is.
The feet must never be removed.
Do not restrict the floor clearance through deep-
pile carpets, strips of wood or similar. This might
cause heat build-up which would interfere with
the operation of the appliance.
Important
The hot air emitted by the tumble dryer can reach
temperatures of up to 60°C. The appliance must
therefore not be installed on floors which are not
resistant to high temperatures.
When operating the tumble dryer, the room temperature
must not be lower than +5°C and higher than +35°C, as
it may affect the performance of the appliance.
P1106
125992050.qxd 4/9/03 9:35 AM Pagina 16 (Nero/Process Black pellicola)