background image

MATEC – ELECTRIC HEATING SYSTEMS

RTP-01 TEMPERATURE CONTROLLER

 

 

INSTRUCTION MANUAL

ZAMEL

 Sp. z o.o.

ul. Zielona 27, 43-200 Pszczyna, Poland

tel. +48 32 449 15 00, +48 32 210 46 65, fax +48 (32) 210 80 04

 

www.zamel.com

, e-mail: 

matec

@zamel.pl

VER. 001_28.06.2016

VER. 001_28.06.2016

TEMPERATURE CONTROL CHARACTERISTICS

KEYBOARD LOCK STATUS

CONTROL IN THE MANUAL AND AUTOMATIC MODE

NOTES

If the temperature from the check sensor is equal or higher than the temperature setting, then the load connected to the terminals (2), (4) is switched off. 

If the temperature from the check sensor is lower by 2°C than the temperature setting, then the load connected to the terminals (2), (4) is switched on. 

The heating symbol on the display is active. The symbol comes off when the temperature in the room reaches the set value. When the sensor is set in 

the MODE – “0” (F5 tab), and if the external sensor detects the increase of the temperature above the upper safety limit, then the heating is switched off. 

At the OFF status the system switches the heating on when the temperature is lower than the safety temperature set in the F3 mode. 

Notes: in the normal operation mode it is possible to set the temperature directly by pressing the “+” / “-” buttons. Pressing the “ ” button for short time 

or no action for 10 minutes makes the system leaving the temperature setting mode.

In the normal operation mode press simultaneously and hold the “+” and “-” buttons to enable/disable the keyboard lock. When the keyboard is locked 

the system is not active and does not respond to pressing buttons, and the “Lock” is shown in the right hand upper corner of the LCD display. 

In the normal operation mode press and hold for about 5 seconds the button “-” to switch between manual and automatic modes. 

Manual mode:

 temperature adjustment in accordance with the set value only, without displaying the operation time range (P1÷P4).

Automatic mode:

 temperature adjustment in accordance with the set value for the current operation time range; the temperature within diverse 

operation time ranges and various working days can be different – in accordance with the program set. 

This symbol informs that the device creates an electric shock hazard when servicing

The system should be serviced by appropriately qualified electricians who has familiarized himself with the operating manual and the functions of the device. 

In the normal operation mode press and hold for about 5 seconds the button “-” to switch between manual and automatic modes. 

Manual mode

: temperature adjustment in accordance with the set value only, without displaying the operation time range (P1÷P4).

Automatic mode

: temperature adjustment in accordance with the set value for the current operation time range; the temperature within diverse 

operation time ranges and various working days can be different – in accordance with the program set. 

Note

Description

After connecting the temperature controller to the power supply 

230 VAC no signs on the display

Check the wiring and the connection of the temperature controller 

with the mains – 230 VAC/50Hz

After pressing any button no backlight comes on 

Backlight system damaged

Temperature in the room is lower by 2 °C 

than the temperature set, 

and in spite of that the floor heating does not come on

Check the pad connection to the temperature controller.

Check the relay operation.

The system does not operate correctly

Switch the power supply off and then switch it on again

The display shows wrong date and time

Caused by a power supply failure for more than 2 hours.

Recheck settings, make new correct ones.

The temperature controller executes 

wrong timed operation program

Caused by a power supply failure for more than 2 hours.

Recheck settings, make new correct ones.

The controller does not execute the timed operation program

The controller set in manual mode.

Switch the controller over to automatic mode.

WARRANTY CARD

There is 24 months guarantee on the product

Salesman stamp and signature, date of sale

1. ZAMEL Sp. z o.o. assures 24 months guarantee for the product.

2. The manufacturer’s guarantee does not cover any of the following actions:

a) mechanical damage during transport, loading / unloading or under other circumstances,

b) damage caused by incorrect product mounting or misuse,

c) damage caused by unauthorised modifications made by the PURCHASER or any third parties to the product or any other devices 

needed for the product functioning,

d) damage caused by Act of God or any other incidents independent of the manufacturer - ZAMEL Sp z o.o.

e) power supply (batteries) to be equipped with a device in the moment of sale (if they appear);

3. The PURCHASER shall lay any claims in writing to the dealer or ZAMEL Sp. z o.o.

4. ZAMEL Sp. z o.o. is liable for processing any claim according to current Polish legislation.

5. ZAMEL Sp. z o.o. shall process the claim at its own discretion: product repair, replacement or money return.

6. The manufacturer’s guarantee is valid in the Republic of Poland.

7. The PURCHASER’s statutory rights in any applicable legislation whether against the retailer arising from the purchase contract or 

otherwise are not affected by this warranty.

APPEARANCE

  This device is to be connected to sin-

gle-phase mains, in accordance with the 

standards in force in the respective country. 

Installation must be carried out according

to this instruction manual. The installation, 

connection and adjustment of the device should be 

carried out by a competent and appropriately qualified, 

licensed electrician who has familiarized himself with 

this instruction manual and the functions of the device. 

Warning!

 Do not remove the casing! Electric shock risk! 

Before installation, dismantling, cleaning, and servicing 

disconnect power supply and make sure the terminals 

are voltage-free. For installing use a straight blade 

screwdriver of the diameter up to 3.5 mm. The correct 

operation of the device is affected by its transportation, 

storage, and use, and particularly how the temperature 

controller and sensor have been installed. Installation 

of this device is not recommended in the following situ-

ations: the lack of parts, damage or deformations of the 

device. If the device does not operate properly, please 

contact the manufacturer.

CAUTION

INSTALLATION

TECHNICAL SPECIFICATIONS

DESCRIPTION

● Disconnect  supply  circuit  by  means  of  a  fuse,  an 

overcurrent protection device or a switch discon-

nector connected to the appropriate circuit.

● Check the voltage free status on supply connectors 

using an appropriate tester.

● Install the RTP-01 device in a room, in accordance 

with the instructions given in the “Description” para-

graph.

● Connect leads to the connecting terminals accord-

ing to the electrical diagram.

● Switch on the power supply circuit.

● Check the operation of the controller and the instal-

lation.

RTP-01 temperature controller is used to control 

the electrical floor heating systems under load. 

The device is installed in a deepened 60 mm  

x 60 mm wiring box.

●  The controller is to be installed in a heated 

room – installation in a deepened 60 mm x

60 wiring box at the height about 120 cm

above the heated floor level. 

●  The controller is to be installed in a safe

place, not exposed to direct sun light, in a

slightly airy area 

●  The temperature and humidity in the instal-

lation place should not exceed the values

listed in the technical specification (T < -5

OR T > +50 °C, relative humidity RH > 90%)

RTP-01

Input (supply) terminals: L (5), N (6)

Input rated voltage: 85 ÷ 265 V~
Nominal frequency: 50 / 60 Hz

Nominal power consumption: 6 mA / 0.4 W (STANDBY)

Battery support: no

NTC sensor terminals: (6), (7)
NTC sensor terminals: NTC 5 k dla 25 ºC

Temperature adjustment range: +5 ÷ +45 °C

Accuracy of temperature measurement: ±1 °C

Control accuracy: 0 °C ÷ -2 °C

Output terminals: (2), (4)

Output type: 1NO-16 A / 250 V AC1 4000 VA voltage contact

Connection terminals quantity: 7

Section of connecting cable: 0,5 ÷ 2,5 mm

2

Ambient temperature range: -5 ÷ +50 °C

Humidity: <90%, no condensation

Installation: deepened wiring box 60 mm x 60 mm

Casing material: polycarbonate (PC)

Casing protection degree: IP40

Protection level: II

Overvoltage category: II

Dimensions: 86 x 86 x 45.5 mm (H x W x D)

Weight: 136 g

Reference standard: EN 60335-1:2002+A2:2006,

EN 61000-3-2:2006, EN 61000-3-3:2006,

EN 55014-1:2006+A1:2009,

EN 55014-2:1997+A2:2008

heating mat

controller

LCD display
LED
ON/OFF button
“–” button
“+” button
Menu button

NTC 5k sensor
N
Heating element
L, fuse, B- characteristics
(6A/10A, power dependent)

The symbol indicates the selective 

collection of the electric and electronic 

equipment. Do not dispose electrical 

and electronic waste together with 

another kind of waste.

Отзывы: