Zamel exta SRP-01/M Скачать руководство пользователя страница 1

ROLLER BLINDS CONTROLLER SRP-01/M 

MANUAL INSTRUCTION

ZAMEL 

Sp. z o.o.

ul. Zielona 27, 43-200 Pszczyna, Poland

tel. +48 (32) 210 46 65, fax +48 (32) 210 80 04

www.zamelcet.com

, e-mail: [email protected]

APPEARANCE

FEATURES

TECHNICAL DATA

DESCRIPTION

SRP-01/M

Input (supply) terminals: L, N, N

Input rated voltage: 230 V AC

Input voltage tolerance:  +10 ÷ -15 %

Nominal frequency: 50 / 60 Hz

Nominal power consumption: 0,12 W („stand-by” mode/) / 0,45 W (roller blind movement)

Optic signalling of roller blind movement:  LED red diode

Maximum time of roller blind movement: 120 sec.

Comfort mode time adjustment: 1 ÷ 120 sec.

Local control cables: LOCAL   (up),   (down)

Central control terminals:  CENTRAL   (up),   (down)

Motor power supply terminals:  (up),   (down)

Relay contact parameters: 2NO 5A / 250V  AC  AC3 1250 VA (voltage contacts)

Number of terminal clamps/cables: 7/2

Section of connecting cables 0,2 ÷ 2,50 mm

2

Ambient temperature range: -10 ÷ +55 

o

C

Operating position:  free

Casing mounting: installation cable box Ø 60 mm

Casing protection degree:  IP20

Overvoltage category: II

Pollution degree: 2

Surge voltage: 1 kV

Dimensions: 38 x 40 x 17,2  mm

Weight: 0,031 kg

●  used in wired control of window roller 

blind, sunblind and gate drives, (elec-

tric motors of 230V AC),

●  local and central control inputs,

●  easily installed in Ø 60 mm junction box,

●  energy-saving  device,  possibility  of 

constant work,

●  operation comfort mode - memory of roll-

er blind height level, (e.g., half-height),

●  possibility of cooperation with any blind 

switch (which is not equipped in back-

light elements),

●  possibility  of  cooperation  with  wire-

less EXTA FREE system by means of 

a  central,  flush  roller  blinds  controller 

SRP-03.

Flush roller blinds controller SRP-

01/M is used in local and/or central con-

trol of window roller blinds or other de-

vices with 230V AC one-phase motors. It 

can operate as an independent controller 

or in sections. The device has two built-

in operation modes - upper and bottom 

(memory of roller blind height level).

The device should be con-

nected to a one-phase network 

in accordance with legally bind-

ing standards. The connection 

method is described in this man-

ual. Any activities related to in-

stallation, connection, and adjustment should 

be  performed  by  qualified  electricians  who 

have read this user’s manual and familiarised 

themselves with device functions. Removing 

the enclosure voids the warranty and poses 

a risk of electric shock. Before installation, 

make sure that there is no voltage on connec-

tion cables. To install the device, use a cross-

head screwdriver with a diameter of 3.5 mm. 

The proper operation of the device is affected 

by how the device is transported, stored, and 

used.  It is not advisable to install the device in 

the following cases: lack of any components, 

damage to or deformation of the device. If the 

device operates improperly, please contact 

the manufacturer.

NOTE

Do not dispose of this device together 

with other waste! To avoid harmful effects 

on the environment and human health, 

the worn-out device should be stored 

in designated areas. Electrical waste 

from households may be handed over 

to the waste collector established for 

this purpose free of change and in any 

amount, as well as to the store when 

purchasing new equipment.

SRP-01_M_inst_ext_GB | 27.10.23

Input (supply) terminals (N, N)

Input (supply) terminal (L)

Central control terminals

(down   / up   movement)

Local control cables

(down   / up   movement)

Motor terminals

(down   / up   movement)

Отзывы: