INSTALLATION EXAMPLES

WARRANTY CARD

Salesman stamp and signature, date of sale.

There is a 24-month guarantee on the product.

MOUNTING

1. Disconnect power supply by the phase 

fuse, the circuit-breaker or the switch-

-disconnector combined to the proper 

circuit.

2. Check if there is no voltage on the con-

nection cables by means of a special 

measuring equipment.

3. Connect the device cables with the ter-

minals in accordance with the installing 

diagram.

4. Mount SRM-11 in a junction box.
5. Switch on the power supply from the 

mains and check if the device operates 

properly.

Grupa rolet

Rozbudowana instalacja roletowa

1.  ZAMEL Sp. z o. o. assures a 24-month guarantee for the product.

2.  The manufacturer’s guarantee does not cover any of the following actions:

a) mechanical damage during transport, loading / unloading or under other circumstances,

b) damage caused by incorrect product mounting or misuse,

c) damage caused by unauthorised modifications made by the PURCHASER or any third parties to the product or any other devices 

required for the product functioning,

d) damage caused by Act of God or any other incidents independent of the manufacturer – ZAMEL Sp. z o. o.

e) power supply (batteries) to be equipped with a device in the moment of sale (if they appear);

3. The PURCHASER shall lay any claims in writing in the place of purchase or to ZAMEL Sp. z o. o.

4. ZAMEL Sp. z o. o. is liable for processing any claim according to current Polish legislation.

5. ZAMEL Sp. z o. o. shall process the claim at its own discretion: product repair, replacement or money return.1

6. The manufacturer’s guarantee is valid in the Republic of Poland.

7. The PURCHASER’s statutory rights in any applicable legislation whether against the retailer arising from the purchase contract or 

otherwise are not affected by this warranty.

The device is designed for a 
single-phase installation and 
must be installed in accor-
dance with standards valid 

in a particular country. Installation, con-
nection and control should be carried out 
by  a  qualified  electrician  staff,  who  act 
in accordance with the instruction ma-
nual and the device functions. In case 
of casing dismantling, the guarantee is 
lost and an electric shock may occur. 
Before installation make sure the con-
nection cables are not under voltage. 
The cruciform head screwdriver 3,5 mm 
should be used to install the device. Im-
proper transport, storage, and use of the 
device  influence  its  wrong  functioning. 
It is not advisable to install the device 
in the following cases: if any device part 
is missing or the device is damaged or 
deformed. In case of improper functio-
ning of the device contact the producer.

CAUTION

The symbol means selective collecting of 

electrical and electronic equipment.  

It is forbidden to put the used equipment 

together with other waste.

CASING DIMENSIONS

CENTRAL

 ROLET

A123

CENTRAL

 GRUP

A1

CENTRAL

 GRUP

A123

CENTRAL

 GRUP

A3

CENTRAL

 GRUP

A2

GRUP

A1

L1

N

L2

N

L3

N

GRUP

A3

GRUP

A2

LOCAL

 ROLETA1

LOCAL

 ROLETA1

LOCAL

 ROLETA5

LOCAL

 ROLETA3

LOCAL

 ROLETA2

LOCAL

 ROLETA2

LOCAL

 ROLETA6

LOCAL

 ROLETA4

LOCAL

 ROLETA3

230 V AC

230 V AC

230 V AC

230 V AC

Содержание exta SRM-11

Страница 1: ...n 5 ZAMEL Sp z o o shall process the claim at its own discretion product repair replacement or money return 1 6 The manufacturer s guarantee is valid in the Republic of Poland 7 The PURCHASER s statutory rights in any applicable legislation whether against the retailer arising from the purchase contract or otherwise are not affected by this warranty The device is designed for a single phase instal...

Страница 2: ...roller or it can be connected in a sections Addi tionally the special functionality of cen tral control inputs allows to lock the roller blind in a closed or opened position The above enables the cooperation with alarm systems and additional devices such as weather station luminous flux intensity sensor rain sensor and control timers N line pulses are the release signals As a result in case of an ...

Страница 3: ...e push button is possible after input connection L and L In this mode after pressing shortly 0 5 sec the local control push button the SRM 11 controller realizes the following functions opening closing or stopping the roller blind equipped with 230 V AC single phase motor Roller blind movement is consistent with time programmed in a controller The default time is 120 seconds The roller blind movem...

Страница 4: ...ly closed roller blind In order to programme the roller blind movement time the following steps are required 1 Close the roller blind completely 2 Press the PROG push button placed on the casing of the SRM 11 controller 3 The roller blind starts opening and simultaneously time is measured Both steps are signalled optically by flashing LEDs which indicate the roller blind movement 4 If the roller b...

Отзывы: