FEATURES
TECHNICAL DATA
DESCRIPTION
APPEARANCE
SEM-01
Maximum voltage range: 300 V~
Number of separators in one casing: 4
Admissible separator’s voltage:
1 A
Maximum voltage drop: 1 V
Number of terminal clamps: 8
Section of connecting cables: 0,2 ÷ 2,50 mm
2
Ambient temperature range: -20 ÷ +45
o
C
Operating position: free
Casing mounting: rail TH 35 (PN-EN 60715)
Casing protection degree: IP20 (PN-EN 60529)
Protection level :
II
Overvoltage category:
II
Pollution degree: 2
Dimensions: monomodular (17,5 mm) 90x17,5x66 mm
Weight: 47 g
Reference standard: PN-EN 60669-1
ی Control signals separation,
ی used in new control systems,
ی four independent separators,
ی monomodular casing,
ی TH 35 rail mounting.
Input separator is used to separate
control signals into particular system
groups, simultaneously blocking the
-
ir access to other groups. The input
separator SEM-01 is used for building
control systems which use exta series
home automation devices. This sys
-
tem allows to subordinate the influen
-
ce of control signals which are led to
releasing inputs. The separator lets
the signal pass one side but blocks the
signal to pass the opposite side. There
are 4 independent separators in one
casing and they can be used in a new
control system.
The device is designed
for one-phase instal
-
lation and must be in
-
stalled in accordance
with standards valid in a
particular country. The
device should be connected according
to the details included in this operating
manual. Installation, connection and
control should be carried out by a qu
-
alified electrician staff, who act in accor
-
dance with the service manual and the
device functions. Casing disassembly
results in breaking the guarantee and
can cause danger of electrocution. Be
-
fore installation make sure the con
-
nection cables are not under voltage.
The cruciform head screwdriver 3,5 mm
should be used to instal the device. Im
-
proper transport, storage, and use of the
device influence its wrong functioning.
It is not advisable to instal the device in
the following cases: if any device part is
missing or the device is damaged or de
-
formed. In case of improper functioning
of the device contact the producer.
CAUTION
VER. 001_12.11.2008
Separa
to
r
’
s
t
ermi
n
al 1
Separa
to
r
’
s
t
ermi
n
al
2
Separa
to
r
’
s
t
ermi
n
al
4
Separa
to
r
’
s
t
ermi
n
al
3