background image

INPUT SEPARATOR SEM-01 

INSTRUCTION MANUAL

Zakład Mechaniki i Elektroniki 

ZAMEL 

sp.j.

J.W. Dzida, K. Łodzińska

ul. Zielona 27, 43-200 Pszczyna, Poland

Tel. +48 (32) 210 46 65, Fax +48 (32) 210 80 04

www.zamelcet.com

, e-mail: [email protected]

FEATURES

TECHNICAL DATA

DESCRIPTION

APPEARANCE

SEM-01

Maximum voltage range: 300 V~

Number of separators in one casing: 4

Admissible separator’s voltage:

1 A

Maximum voltage drop: 1 V

Number of terminal clamps: 8

Section of connecting cables: 0,2 ÷ 2,50 mm

2

Ambient temperature range: -20 ÷ +45 

o

C

Operating position: free

Casing mounting: rail TH 35 (PN-EN 60715)

Casing protection degree: IP20 (PN-EN 60529)

Protection level :

II

Overvoltage category:

II

Pollution degree: 2

Dimensions: monomodular (17,5 mm) 90x17,5x66 mm

Weight: 47 g

Reference standard: PN-EN 60669-1

ی  Control signals separation,
ی  used in new control systems,
ی  four independent separators,
ی  monomodular casing,
ی  TH 35 rail mounting.

Input separator is used to separate 

control  signals  into  particular  system 

groups, simultaneously  blocking the

-

ir  access  to  other  groups.  The  input 

separator SEM-01 is used for building 

control systems which use exta series 

home  automation  devices.  This  sys

-

tem allows to subordinate the influen

-

ce of control signals which are led to 

releasing  inputs.  The  separator  lets 

the signal pass one side but blocks the 

signal to pass the opposite side. There 

are  4  independent  separators  in  one 

casing and they can be used in a new 

control system.

The  device  is  designed 

for  one-phase  instal

-

lation  and  must  be  in

-

stalled  in  accordance 

with standards valid in a  

particular  country.    The 

device  should  be  connected  according  

to the details included in this  operating 

manual.  Installation,  connection  and 

control should be  carried out by a qu

-

alified electrician staff, who act in accor

-

dance with  the service manual and the 

device  functions.  Casing  disassembly 

results  in  breaking  the  guarantee  and 

can cause danger of electrocution. Be

-

fore    installation    make  sure  the  con

-

nection  cables  are  not  under  voltage.  

The cruciform head screwdriver 3,5 mm 

should be used to  instal the device. Im

-

proper transport, storage, and use of the 

device  influence  its  wrong  functioning.  

It is not advisable to instal the device in 

the following cases:  if any device part is 

missing or the device is damaged or de

-

formed. In case of  improper functioning 

of the device contact  the producer.