MICROWAVE MOTION SENSOR
MCR-01
USER MANUAL
ZAMEL
Sp. z o.o.
ul. Zielona 27, 43-200 Pszczyna, Poland
Tel. +48 (32) 210 46 65, Fax +48 (32) 210 80 04
www.zamelcet.com, e-mail: [email protected]
MCR-01_inst_ext_GB | 23.04.21
APPEARANCE
FEATURES
DESCRIPTION
• The motion detector is designed for plac-
ing within lighting fittings, plastic casings,
under suspended ceilings, behind light
partition walls, etc.
• movement detection through glass, plas-
tic and cardboard-gypsum plate obsta-
cles,
• high sensitivity and excellent motion de-
tection regardless of the movement direc-
tion,
• temperature changes do not affect detec-
tion quality,
• protection degree IP20.
The microwave motion detector is an
active device.The integrated device trans-
mits high frequency electromagnetic waves
(5,8 GHz) and receives the wave echo. The
device detects any echo changes within
the working zone. When such changes are
detected the CPU gives TURN THE LIGHT
ON command. Thanks to its high sensitivity
the device is capable of detecting move-
ment through the doors, glass obstacles or
cardboard-gypsum plates.
Detection zones
(mounted on the ceiling)
Zone diameter: 3 ÷ 10 m
Detection zones
(mounted on the wall)
Zone diameter: 3 ÷ 10 m
NOTE! The best device sensitivity is for
people and objects moving towards the
detector.
TECHNICAL DATA
MCR-01
Input rated voltage: 220 ÷ 240 V 50/60Hz
Operating frequency: 5,8 GHz
Rated power output consumption: 0,9 W
Operating range: minimum: a circle (3 m diameter)
maximum: a circle (9 m diameter)
Operating field adjustment: fluent (rotational potentiometer)
Motion detection angle: 360
o
, with an open angle of 160
o
Transmitting rated power: < 10 mW
Lighting switch on time: 8 s ÷ 12 min. - fluent adjustment
Maximum lighting source rated power:
1200 W,
21 W,
30 W
Lighting sensor: inner
Lighting sensor range adjustment: 2 ÷ 2000 lux - fluent adjustment
Protection degree: IP20
Protection class: II
Dimensions: 90 x 41,5 x 41,5 mm
Weight: 0,07 kg
NOTE!
The 230 V AC power supply model is a transformerless device. Only authorised
technician is allowed to mount the device.
Detection zone:
mounted on the ceiling mounted on the wall
Power supply
terminals
Motion sensor
Lighting sensor