FEATURES

TECHNICAL PARAMETERS

DESCRIPTION 

APPEARANCE

ver. 0.4.2 _ 2006.06.20_11:00

ی  Graphic  presentation  of  the  one-

phase  voltage  supply  system  le

-

vel,

ی  voltage indication wide range from 

195 to 245 V~,

ی  voltage value proportional to graph 

height scale range 5 V,

ی  indication stability,
ی  indicated  voltage  value  accuracy 

±

2,5 V,

ی  voltage  critical  values  are  signal

-

led  by  diodes  marked  „≤195  V”, 

„≥245 V”, 

ی  TH-35 DIN rail installation.

LDM - 10

Input (supply) terminals: L, N

Input rated voltage: 230 V~

Input voltage tolerance: from -15 to +10 %

Rated frequency: 50 / 60 Hz

Rated power consumption:  24 mA

Voltage indicator: 11 LED diodes

Voltage indicator accuracy: ±2,5 V

Number of  terminal clamps:

2

Section of connecting cables: from 0,2 to 2,5 mm

2

Ambient temperature range: from -20 to +45 

o

C

Operating position: free

Mounting: TH35 rail (PN-EN 60715)

Protection degree: IP20 (PN-EN 60529)

Protection class:

II

Overvoltage category:

II

Pollution degree:

2

Impulse voltage: 1 kV (PN-EN 61000-4-5)

Dimensions (height / width / depth): monomodular (17,5 mm) 90x17,5x66 mm

Weight: 56 g

Reference standards: PN-EN 60947-5-1, PN-EN 60947-1

PN-EN 61000-4-2,3,4,5,6,11

The  LDM-10  device  is  used  for 

graphic presentation of the one-phase 

voltage  supply  system  level.  Voltage 

value  is  shown  by  means  of  a  diode 

line  of  11  LED  diodes.  The  range  of 

measure is from 195 to 245 V ~.

Zakład Mechaniki i Elektroniki 

ZAMEL 

sp.j.

J.W. Dzida, K. Łodzińska

ul. Zielona 27, 43-200 Pszczyna, Poland

Tel. +48 (32) 210 46 65, Fax +48 (32) 210 80 04

www.zamel.pl, 

e-mail:

 [email protected]

The  device  is  designed 
for one-phase installation 
and  must  be  installed  in 
accordance with standar

-

ds valid in a particular co

-

untry.  The  device  should 

be  connected  according  to  the  details 
included in this operating manual. Instal

-

lation, connection and control should be 
carried out by a qualified electrician staff, 
who  act  in  accordance  with  the  service 
manual and the device functions. Disas

-

sembling  of  the  device  is  equal  with  a 
loss of guarantee and can cause electric 
shock. Before installation  make sure the 
connection cables are not under voltage. 
The cruciform head screwdriver 3,5 mm 
should be used to instal the device. Im

-

proper transport, storage, and use of the 
device  influence  its  wrong  functioning. 
It is not advisable to instal the device in 
the following cases: if any device part is 
missing or the device is damaged or de

-

formed. In case of improper functioning 
of the device contact  the producer.

CAUTION

I

nput

 

(supply

 / 

m

e

asu

re

)

 

V

oltag

indicato

r

I

nput

 

(supply)

 

t

er

minals

 

(

N

)

terminals (L)

Отзывы: